SWH-IOM (08/10)
Page 15
5. EarthLinked
®
Hydronic Heating and Chilled Water Cooling (HWM)
Applications
Hydronic Heating Only:
Figure 5a illustrates the installation of a GSTE storage water heater with the Hydronic Water
Module (HWM) providing heated water (only) to a hydronic system. Location of the storage
water heater from the HWM is to be no more than 10 ft. apart. Water piping and fittings
between the HWM and the storage water heater are to be 1” Type L copper for model HWM-
1836, and 1-1/2” Type L copper for models HWM-4248 and HWM-6072. Detail for the ports
and connections on top of the tank are illustrated in Figure 5b. The electrical field wiring for the
HHK-1872 temperature controller and the electric heater element and thermostat are illustrated
in Figure 5c.
Figure 5a. Hydronic Heating (HWM) Application
Summary of Contents for GSTE-119
Page 5: ...SWH IOM 08 10 Page 5 Figure 1 GSTE Storage Water Heater Description...
Page 7: ...SWH IOM 08 10 Page 7 Figure 2b Top of Tank Connections CWH...
Page 8: ...SWH IOM 08 10 Page 8 Figure 2c Electrical Field Wiring CWH...
Page 10: ...SWH IOM 08 10 Page 10 Figure 3b Top of Tank Connections DWM...
Page 11: ...SWH IOM 08 10 Page 11 Figure 3c Electrical Field Wiring DWM...
Page 13: ...SWH IOM 08 10 Page 13 Figure 4b Top of Tank Connections Desuperheater...
Page 14: ...SWH IOM 08 10 Page 14 Figure 4c Electrical Field Wiring Desuperheater...
Page 16: ...SWH IOM 08 10 Page 16 Figure 5b Top of Tank Hydronic Heating HWM...
Page 25: ...SWH IOM 08 10 Page 25...