1. General Description of Applications
The GSTE-60, GSTE-80 and GSTE-119 Storage Water Heaters are applied to the following
EarthLinked
®
systems. Installation instructions for each of these applications follow.
•
Earthlinked
®
Commercial Water Heating Applications
providing heated
potable
water
from the compressor unit and delivered to a storage water heater, where reserve
electric heating is required if the compressor unit is out of service. The electric heat
would be activated manually at the breaker if the compressor unit is taken off line. This
application is detailed in Section 2.
•
EarthLinked
®
Domestic Water Heating Applications utilizing the Domestic Water
Module (DWM)
providing heated
potable water
from the DWM and delivered to a
storage water heater, where reserve electric heating element is required if the
compressor unit is out of service. The electric heat would be activated manually at the
breaker if the compressor unit is taken off line. This application is detailed in Section 3.
•
EarthLinked
®
Desuperheater Water Heating Applications utilizing the SD
Compressor Unit
(equipped with a desuperheater) or the
Model DSH-1872
Desuperheater Kit applied to an SC or SW compressor unit
providing heated
potable water
to supplement the standard electric storage water heater.
In this
application, the desuperheater operates to heat water when the EarthLinked
®
Heating
and Cooling System is operating in cooling mode. The desuperheater functions to
supplement, but not replace, the water being heated by the standard storage water
heater. This application is detailed in Section 4.
•
EarthLinked
®
Hydronic Heating and Chilled water Cooling Applications utilizing
the Hydronic Water Module (HWM)
providing heated
hydronic water solution
from
the HWM and delivered to the storage water heater (the primary circuit) where an
electric heating element supplements the heating of the hydronic water solution as a
function of outdoor temperature, controlled by an outdoor thermostat. This application is
detailed in Section 5.
The EarthLinked
®
Model GSTE Storage Water Heater description appears in Figure 1. In
addition to the storage water heater, temperature control Model HHK-1872 is required for
commercial water heating, domestic water heating and radiant panel hydronic heating
applications; and the temperature control Model CWK-1872 is required for chilled water cooling
applications.
Summary of Contents for GSTE-119
Page 5: ...SWH IOM 08 10 Page 5 Figure 1 GSTE Storage Water Heater Description...
Page 7: ...SWH IOM 08 10 Page 7 Figure 2b Top of Tank Connections CWH...
Page 8: ...SWH IOM 08 10 Page 8 Figure 2c Electrical Field Wiring CWH...
Page 10: ...SWH IOM 08 10 Page 10 Figure 3b Top of Tank Connections DWM...
Page 11: ...SWH IOM 08 10 Page 11 Figure 3c Electrical Field Wiring DWM...
Page 13: ...SWH IOM 08 10 Page 13 Figure 4b Top of Tank Connections Desuperheater...
Page 14: ...SWH IOM 08 10 Page 14 Figure 4c Electrical Field Wiring Desuperheater...
Page 16: ...SWH IOM 08 10 Page 16 Figure 5b Top of Tank Hydronic Heating HWM...
Page 25: ...SWH IOM 08 10 Page 25...