42
SLB-Series User Manual
Error Codes
Category
Title
Error details and possible causes
File operation
File exist
The USB has the file with the same name
Open err
Unable to open the file in the USB
Not USB
Unable to identify USB
Create file err
Create file unsuccessful to the USB
Save file err
Save file unsuccessful to the USB
Save alloc err
The USB’s FAT operation failed
Save Error
The native file save error, file length etc.
Version Error
The current version cannot view the native storage file.
Version without grouping cannot view the storage data
files with grouping version. Vice versa.
Memory Full
The native storage space is not enough to store the
setting time data file as discreet value
Parallel
communication
Set paral load fail
The discharge communication between the loads failed
load failure
Communication before discharging with the load failed
and/or parameter setting is incorrect or met
Load Total U too high Detected total voltage of load before discharge is greater
than the maximum voltage limit
Total batteries voltage
inconformity
Detected total voltage of load before discharge is not in
the host’s current selected voltage type
Extension
communication
DAC error
communication with the Com Terminal failed
Parameter setting Set Error
parameter setting value and save values are not
consistent.
Coefficient Error
Calibration coefficient of deviation is too large
Total U too high
Detected before discharge total voltage is greater than
the maximum voltage limit
U low
Total voltage detected before discharge is less than the
total end voltage value parameter setting
www.