23
STEP 14
Start Up
1] Make sure the reservoir is filled with
AW-32 hydraulic oil
.
2] Spray inside corners of columns, where the guide blocks slide, with lithium grease.
3] Press the “UP” switch on the power unit. Lift will slowly raise.
IF THE LIFT DOES NOT RAISE
CHECK
hose connections:
Fluid should be pumping through the hose connected to the Power Unit.
CHECK
fluid level:
Verify pick-up tube inside reservoir is connected to pump.
CHECK
electrical connection:
Verify 220v, 20@, 1ph connection is properly wired.
CHECK
Power Unit Priming:
See “
Priming Procedure
”, page 20.
NOTE: There will be some initial stretching of the cables in the beginning.
It will be necessary to re-adjust the cables a week after first use.
Then every six (6) months thereafter.
4] Run the lift up and down a few times to bleed the hydraulic system then top off the reservoir
with the lift in the fully lowered position.
5] Be sure that both carriage locks are clicking simultaneously and that the arm safety
mechanisms are functioning properly. Re-adjust the cables until the carriage locks click in sync if
necessary. This is accomplished by tightening the cable on the side that is clicking first.