11
INSTALLATION
STEP 1
Selecting the Site
Your lift requires
220v, 20amp, single phase
electrical power. The area of operation should
provide the minimum space shown above (Fig. 2). There should be room enough to operate the
lift in a safe manner and without restrictions. The area should be kept clean of oil, grease, etc.,
and clear of clutter. Avoid areas where customers or other bystanders may be present.
Before installing your lift, check the following:
1] LIFT LOCATION
: Always use architect’s plans when available. Check layout dimension (fig. 2)
against floor plan requirements making sure adequate space is available.
2] OVERHEAD OBSTRUCTIONS:
The area where the lift will be located should be free of
overhead obstructions such as heaters, building supports, electrical lines, doors, etc.
3] DEFECTIVE FLOOR:
Visually inspect the site where the lift is to be installed and check for
cracked or defective concrete.
4.] OPERATING TEMPERATURE:
Only operate lift between temperatures of 41-104 degrees
Fahrenheit.
ATTENTION: This lift is intended for indoor installation only.
Improper installation may result in voiding of warranty,
damage to lift and property, and/or personal injury.