1260-45 User Manual
Module Specification 1-2
EADS North America Defense
Test and Services, Inc. © 1993
Maximum Switchable Voltage
(Terminal-Terminal or
Terminal-Chassis)
300 VDC, 300 VAC
Maximum Switchable Power
Per Channel
30W, 62.5 VA (Resistive Load)
Path Resistance
Worst Case
< 1.6
Ω
End
of
Life
<
2.5
Ω
Isolation Hi-Lo
> 100 M
Ω
Capacitance
Open
Channel
<100
pF
Channel-Chassis
<200
pF
Hi-Lo
<200
pF
Minimum Bandwidth 50
Ω
Termination
25 MHz (4 x 16)
25 MHz (4 x 32)
20 MHz (4 x 64)
10
MHz
(16
x
16)
Insertion Loss, 50
Ω
Termination
< 1 dB to 100 kHz
<
1.5
dB
to
1
MHz
Crosstalk, 50
Ω
Termination
< -50 dB to 100 kHz
(4X16)
-50
dB
to
1
MHz
Cooling
Airflow
4.0
litres/sec.
Backpressure
0.5mm
H
2
0
Power (I
pm
)
+5V
.4A
(2.8A
Option
01
installed)
+24V
0.16A
Weight
3.07
lbs.
(1.38kg)
3.35
lbs.
(1.51kg)
w/
Opt
01
User Connector
64-Pin (2 rows)
IDC
Quick
Disconnect*
∗
A crimp connector kit is also available for this module (P/N
407051-001). A strain relief option can be ordered separately
for this crimp connector kit, P/N 407207.