1260-45 User Manual
EADS North America Defense
Module Specific Syntax 3-3
Test and Services, Inc. © 1993
PSETUP Command
The PSETUP command causes the specified module to transmit
its sequence mode. The supported sequence modes are IMM
(Immediate), BBM (Break-Before-Make), and MBB (Make-Before-
Break). The syntax used is:
PSETUP <mod addr>[;<mod addr>][;<mod addr>]....
The response to the PSETUP command is as follows:
<header>
<mod addr>.<seq mode>
<mod
addr>.END
where <seq mode> is IMM, BBM, or MBB, and
where <header> is as follows:
1260-45A: <mod addr>. 1260-45A Quad 4x16 SIGNAL MATRIX
MODULE
1260-45B: <mod addr>. 1260-45B Dual 4x32 SIGNAL MATRIX
MODULE
1260-45C: <mod addr>. 1260-45C Dual 4x32 SIGNAL MATRIX
MODULE
Note the actual <header> sent is determined by the setting of the
ID Byte DIP switches on the module, and is independent of any
external user configuration cables.
The 1260-45 supports most standard 1260 features. These
include Confidence Mode, Equate/Exclude/Scan Lists commands,
and the STORE/RECALL commands.
Connector Pin
Configuration
Refer to
Figure 3-1
for pin configurations of the front panel
connectors J200 to J203. J200 to J203 is Part Number 602005.
The part numbers for the mating connectors and discrete wire
connectors are shown below. The actual pinouts are given in
Table 3-1
and
Figure 3-2
.
Mating Connectors
602004
Connector Body
602004-001
Strain Relief
602004-002
Pull Tabs
Crimp (Discrete Wire Connectors)
602159-064
Body
602159-900
Pins
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com