background image

 

 

 

RETURN of PRODUCT 

Authorization is required from EADS North America Defense Test and Services, Inc. before you send us your 
product for service or calibration.  Call or contact the Customer Support Department at 1-800-722-3262 or 1-
949-859-8999 or via fax at 1-949-859-7139.  We can be reached at: 

[email protected]

 

PROPRIETARY NOTICE 

This document and the technical data herein disclosed, are proprietary to EADS North America Defense Test 
and Services, Inc., and shall not, without express written permission of EADS North America Defense Test 
and Services, Inc., be used, in whole or in part to solicit quotations from a competitive source or used for 
manufacture by anyone other than EADS North America Defense Test and Services, Inc.  The information 
herein has been developed at private expense, and may only be used for operation and maintenance 
reference purposes or for purposes of engineering evaluation and incorporation into technical specifications 
and other documents which specify procurement of products from EADS North America Defense Test and 
Services, Inc. 

 

DISCLAIMER 

Buyer acknowledges and agrees that it is responsible for the operation of the goods purchased and should 
ensure that they are used properly and in accordance with this handbook and any other instructions provided 
by Seller.  EADS North America Defense Test and Services, Inc. products are not specifically designed, 
manufactured or intended to be used as parts, assemblies or components in planning, construction, 
maintenance or operation of a nuclear facility, or in life support or safety critical applications in which the 
failure of the EADS North America Defense Test and Services, Inc. product could create a situation where 
personal injury or death could occur.  Should Buyer purchase EADS North America Defense Test and 
Services, Inc. product for such unintended application, Buyer shall indemnify and hold EADS North America 
Defense Test and Services, Inc., its officers, employees, subsidiaries, affiliates and distributors harmless 
against all claims arising out of a claim for personal injury or death associated with such unintended use. 

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for Racal Instruments 1260-45

Page 1: ...erutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In st...

Page 2: ...nadefense com helpdesk eads nadefense com http www eads nadefense com PUBLICATION DATE March 25 2005 Copyright 1993 by EADS North America Defense Test and Services Inc Printed in the United States of...

Page 3: ...ten consent or misuse of any product or part The warranty also does not apply to fuses software non rechargeable batteries damage from battery leakage or problems arising from normal wear such as mech...

Page 4: ...of products from EADS North America Defense Test and Services Inc DISCLAIMER Buyer acknowledges and agrees that it is responsible for the operation of the goods purchased and should ensure that they...

Page 5: ...is will defeat the protective feature of the third conductor in the power cord Maintenance and calibration procedures sometimes call for operation of the unit with power applied and protective covers...

Page 6: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 7: ...This page was left intentionally blank Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 8: ...e to be used for the 1260 01T The syntax of the commands which use channel numbers has changed for those cards controlled by the 1260 01T The new syntax used to close a channel is CLOSE module address...

Page 9: ...e suppose the following setup A24 Address Assigned to 1260 01T by Resource Manager 204 00016 Module Address of 1260 45 7 Then the A24 Base Address for the 1260 45 Module would be 204 00016 7 x 40016 1...

Page 10: ...bit 0 8 0x01 CWADDR2 bit 1 9 0x02 CWADDR2 bit 2 10 0x04 CWADDR2 bit 3 11 0x08 CWADDR2 bit 4 12 0x10 CWADDR2 bit 5 13 0x20 CWADDR2 bit 6 14 0x40 CWADDR2 bit 7 15 0x80 The following procedure may be us...

Page 11: ...o operate 1 1 to close relays in row 0 2 2 to close relays in row 1 3 4 to close relays in row 2 4 8 to close relays in row 3 4 Wait 4 milliseconds 5 Write the value 0 to CROWADDR1 or CROWADDR2 Exampl...

Page 12: ...nd Inspection 2 1 Reshipment Instructions 2 1 Option 01 Installation 2 1 Module Installation 2 2 Chapter 3 3 1 MODULE SPECIFIC SYNTAX 3 1 Module Specific Command Syntax 3 1 Syntax 3 1 PDATAOUT Command...

Page 13: ...HARNESS ASSEMBLIES 5 1 Chapter 6 6 1 PRODUCT SUPPORT 6 1 Product Support 6 1 Warranty 6 1 Appendix A A 1 HOW TO CONFIGURE THE 1260 45 MATRIX MODULE A 1 Introduction A 1 Configuration A 1 Larger Matri...

Page 14: ...umns A 3 Figure A 2 J200 J202 Block Diagram A 3 Figure A 3 J201 J203 Block Diagram A 4 Figure A 4 1260 45A Quad 4X16 Matrices A 4 Figure A 5 1260 45B Dual 4X32 Matrices A 5 Figure A 6 1260 45C Dual 8X...

Page 15: ...1260 45 User Manual iv This page was left intentionally blank Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 16: ...The performance specifications given below are for a single 4 x 16 array 1260 45 Module Specifications Factory Configurations 1260 45A Quad 4 x 16 1260 45B Dual 4 x 32 1260 45C Dual 8 x 16 Additional...

Page 17: ...16 25 MHz 4 x 32 20 MHz 4 x 64 10 MHz 16 x 16 Insertion Loss 50 Termination 1 dB to 100 kHz 1 5 dB to 1 MHz Crosstalk 50 Termination 50 dB to 100 kHz 4X16 50 dB to 1 MHz Cooling Airflow 4 0 litres sec...

Page 18: ...revent electrostatic damage to the module Do not remove the module from the anti static bag unless it is in a static controlled area Reshipment Instructions 1 Use the original packing when returning t...

Page 19: ...to a VXI mainframe including the setting of DIP switches is described in the Installation section of the 1260 Series VXI Switching Cards Manual Publication No 986673 The ID byte DIP switch SW1 should...

Page 20: ...for the 1260 45 Quad 4 x 16 Signal Matrix module is as follows mod addr grp no row no col no where mod addr is the switch card address NOTE The mod addr used here is not the VXIbus defined logical add...

Page 21: ...tions respond to the same sets of values for grp no row no and col no PDATAOUT Command The PDATAOUT command causes the specified module to transmit the CLOSED state of the relays The syntax used is PD...

Page 22: ...MATRIX MODULE Note the actual header sent is determined by the setting of the ID Byte DIP switches on the module and is independent of any external user configuration cables The 1260 45 supports most...

Page 23: ...2 42 32 22 12 01 91 81 71 61 51 41 31 21 11 0 9 8 7 6 5 4 3 2 1 3 23 13 02 92 82 72 62 52 42 32 22 12 01 91 81 71 61 51 41 31 21 1 1 0 9 8 7 6 5 4 3 2 1 3 23 13 02 92 82 72 62 52 42 32 22 12 01 91 81...

Page 24: ...B14 10 J202 A12 J202 B12 11 J202 A10 J202 B10 12 J202 A8 J202 B8 13 J202 A6 J202 B6 14 J202 A4 J202 B4 15 J202 A2 J202 B2 Grp Row Hi Pin Lo Pin Col Hi Pin Lo Pin 1 0 J200 A20 J200 B20 0 J202 A31 J202...

Page 25: ...J203 B14 10 J203 A12 J203 B12 11 J203 A10 J203 B10 12 J203 A8 J203 B8 13 J203 A6 J203 B6 14 J203 A4 J203 B4 15 J203 A2 J203 B2 Grp Row Hi Pin Lo Pin Col Hi Pin Lo Pin 3 0 J201 A20 J201 B20 0 J203 A31...

Page 26: ...t and Services Inc 1993 Chassis Ground J200 A1 A4 A19 A21 A23 A25 A27 A29 A31 B1 B4 B19 B21 B23 B25 B27 B29 B31 J201 A1 A4 A19 A21 A23 A25 A27 A29 A31 B1 B4 B19 B21 B23 B25 B27 B29 B31 Artisan Technol...

Page 27: ...26 B28 A28 B30 A30 B32 A32 B1 A1 B3 A3 B5 A5 B7 A7 B9 A9 B11 A11 B13 A13 B15 A15 B17 A17 B19 A19 B21 A21 B23 A23 B25 A25 B27 A27 B29 A29 B31 A31 L H L H L H L H L H L H L H L H L H L H L H L H L H L H...

Page 28: ...6 B28 A28 B30 A30 B32 A32 B1 A1 B3 A3 B5 A5 B7 A7 B9 A9 B11 A11 B13 A13 B15 A15 B17 A17 B19 A19 B21 A21 B23 A23 B25 A25 B27 A27 B29 A29 B31 A31 L H L H L H L H L H L H L H L H L H L H L H L H L H L H...

Page 29: ...f each module for this purpose Connector 3 is the regular user interface The mate to this connector can be a discrete wire connector or a ribbon cable depending upon user preferences Connectors 1 and...

Page 30: ...8 x 32 1260 45B Columns with Loopback 16 x 16 1260 45C Columns with Loopback 8 x 64 4 x 64 2 modules Columns with Loopback Between Modules LBBM 16 x 32 8 x 32 2 modules Columns with Loopback Between M...

Page 31: ...ual Module Specific Syntax 3 12 EADS North America Defense Test and Services Inc 1993 This page was left intentionally blank Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE w...

Page 32: ...oils are only energized when their state is to be changed Several features have been incorporated into the card to reduce the time necessary to update the state of the relays on the card First relay c...

Page 33: ...or OFF Referring to Figure 4 1 assume the relay coil on K1 between pins 1 and 5 is actuated This means all drivers are OFF except for U1 Pin 18 and U2 Pin 18 Under normal conditions this will cause th...

Page 34: ...Figure 4 1 Relay Drive Circuitry U1 U2 K1 K2 CR1 CR2 CR3 CR4 18 17 18 17 1 10 1 10 5 6 5 6 Z1B 220 Z1A 220 Z2A 47K THA Z2B 47K Z3A 33K Z3B 33K R1 5 23K 6 7 4 5 U3A U3B 2 1 Z4A Z4B 5V 2 4V R2 10K Arti...

Page 35: ...ser Manual Operation 4 4 EADS North America Defense Test and Services Inc 1993 This page was left intentionally blank Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www arti...

Page 36: ...ch harness documentation consists of an assembly drawing parts list system wire list and wire list 407286 Virginia Panel Inc Series VP90 Interface Harness 407287 TTI Testron Inc Interface Harness TTI...

Page 37: ...l Optional Harness Assemblies 5 2 EADS North America Defense Test and Services Inc 1993 This page was left intentionally blank Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE...

Page 38: ...INC T IT LE CAGE CODE 2 3 4 3 4 5 6 8 1 DWG NO 5 8 7 A B C D REV SH 4 Goodyear S t Irvine CA 92718 2002 1 NONE C 1 7 407286 980346 REV F 1 C 407286 NOT ES UNLES S OT HERWIS E S PECIFIED S EE SE P ARA...

Page 39: ...0000 J100 J101 2 407259 CABLE ASSY IDC 64COND VP90 EA 2 00000 J202 J203 3 407356 CABLE ASSY IDC 32COND VP90 EA 2 00000 J200 J201 4 910541 POLYURETHANE CONFORMAL COAT EA 00001 5 GRP l10 1 2 TBGWOV POY...

Page 40: ...1260 45 User Manual EADS North America Defense Optional Harness Assemblies 5 5 Test and Services Inc 1993 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 41: ...1260 45 User Manual Optional Harness Assemblies 5 6 EADS North America Defense Test and Services Inc 1993 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 42: ...1260 45 User Manual EADS North America Defense Optional Harness Assemblies 5 7 Test and Services Inc 1993 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 43: ...1260 45 User Manual Optional Harness Assemblies 5 8 EADS North America Defense Test and Services Inc 1993 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 44: ...1260 45 User Manual EADS North America Defense Optional Harness Assemblies 5 9 Test and Services Inc 1993 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 45: ...1260 45 User Manual Optional Harness Assemblies 5 10 EADS North America Defense Test and Services Inc 1993 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 46: ...1260 45 User Manual EADS North America Defense Optional Harness Assemblies 5 11 Test and Services Inc 1993 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 47: ...1260 45 User Manual Optional Harness Assemblies 5 12 EADS North America Defense Test and Services Inc 1993 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 48: ...1260 45 User Manual EADS North America Defense Optional Harness Assemblies 5 13 Test and Services Inc 1993 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 49: ...1260 45 User Manual Optional Harness Assemblies 5 14 EADS North America Defense Test and Services Inc 1993 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 50: ...1260 45 User Manual EADS North America Defense Optional Harness Assemblies 5 15 Test and Services Inc 1993 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 51: ...1260 45 User Manual Optional Harness Assemblies 5 16 EADS North America Defense Test and Services Inc 1993 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 52: ...1260 45 User Manual EADS North America Defense Optional Harness Assemblies 5 17 Test and Services Inc 1993 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 53: ...1260 45 User Manual Optional Harness Assemblies 5 18 EADS North America Defense Test and Services Inc 1993 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 54: ...complete the form in the back of this manual For worldwide support and the office closest to your facility refer to the website for the most complete information http www eads nadefense com Warranty...

Page 55: ...e Country Technical Contact Phone Number Purchasing Contact Phone Number 1 Describe in detail the problem and symptoms you are having Please include all set up details such as input output levels freq...

Page 56: ...rcuit boards mounted one on top of the other See Figures A 1 and A 2 for a block diagram of the module Modules may be purchased from the factory with internal jumpers installed Following are the three...

Page 57: ...d J201 on each module to achieve the 8 rows Connect J202 to J203 on each of the modules to give you the 64 columns See Figure A 8 We could easily have started with a 1260 45C because in this example s...

Page 58: ...6 A6 B8 A8 B10 A10 B12 A12 B14 A14 B16 A16 B18 A18 B20 A20 B22 A22 B24 A24 B26 A26 B28 A28 B30 A30 B32 A32 B1 A1 B3 A3 B5 A5 B7 A7 B9 A9 B11 A11 B13 A13 B15 A15 B17 A17 B19 A19 B21 A21 B23 A23 B25 A25...

Page 59: ...A1 B3 A3 B5 A5 B7 A7 B9 A9 B11 A11 B13 A13 B15 A15 B17 A17 B19 A19 B21 A21 B23 A23 B25 A25 B27 A27 B29 A29 B31 A31 L H L H L H L H L H L H L H L H L H L H L H L H L H L H L H L H 15 14 13 12 11 10 9 8...

Page 60: ...4 1 3 16 16 0 2 16 16 1 3 J200 J201 1260 45B PIN 1 PIN 1 ROW ROW A B TYPICAL FOR ALL 4 CONNECTORS INTERNAL JUMPERS PARALLEL ROW ON GROUP 0 1 GROUP 2 3 GND GND 4 0 4 2 4 4 1 3 16 16 0 2 16 16 1 3 J200...

Page 61: ...ca Defense Test and Services Inc 1993 Figure A 7 1260 45B Configured as 4X64 Matrix Figure A 8 1260 45B Configured as 8X64 Matrix 1260 45 J200 J201 J202 J203 ROW 1 4 COLUMN 33 64 COLUMN 1 32 Artisan T...

Page 62: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Reviews: