Technical features

I – Technical specifications

Sensing elements
Pressure module 

Piezoresistive sensor

Overpressure allowed ±500 Pa : 250 mbar
Overpressure allowed ±2,500 Pa : 500 mbar
Overpressure allowed ±10,000 Pa : 1,200 mbar
Overpressure allowed ±500 mbar : 2 bar
Overpressure allowed ±500 mbar : 2 bar

Hotwire:

  Thermistance with a negative temperature coefficient

Ambient temperature : Pt100  1/3 Din.

Ø 70 and 100 mm vane probes : 

Hall effect sensor

Ambient temperature : Pt100 class A.

Ø 14 mm vane probe: 

Proximity sensor

Ambient temperature : Pt100 class A.

Hygrometry/Temp. probes:

 capacitive sensor Pt100 1/3 DIN

Thermocouple probes :

 type K, J and T class 1

Smart-plus Pt100 probes

 

:

 Pt100 class 1/3 Din

Climatic conditions module:

Hygrometry :

 capacitive sensor

Temperature : 

semiconductor sensor

Air pressure :

 piezoresistive sensor

Air quality probes

CO

2

 : 

NDIR sensor

CO : 

electrochemical sensor

Temperature : 

Pt100 class A 

Hygrometry :

 capacitive sensor

Climatic conditions module:

Hygrometry :

 capacitive sensor

Temperature : 

semiconductor sensor

Air pressure :

 piezoresistive sensor

Multifunction probe

Air velocity : 

Thermistance with a negative temperature 

coefficient

Hygrometry/Temp.:  

Capacitive sensor,  Pt100 1/3 DIN

Tachometry sensor

Optical 

: optical sensor

Contact : 

optical probe with ETC adaptor

Instrument connections

..........

On the top

 :

2 secured mini-Din connectors for SMART-plus probe

s

Left side :

1 USB port for E Instruments cable only
1 power supply plug

Modules connections

.................

T

hermocouple 

4

 

inputs  for compensated miniature 

plug of thermocouple  K, J or T type 
Class 1 (as per IEC 584-3) 

Pressure

2 pressure connectors Ø 6,2 mm made of 
 nickel brass
2 threaded pressure connectors Ø 4,6 mm made of  
nickel brass (for  500 and  200 mbar)
+ 1 temperature thermocouple input for miniature 

   

connector

current/Voltage module

2 stereo jacks

Display

.........................................Graphic display 320x240 pixels

 

Dim. 70 x 52 mm.
Color display
Display of  6 measurements (including  4 simultaneously)

Housing

........................................ABS shock-proof, IP54

Keypad

.........................................Metal-coated, 5 keys, 1 joystick 

Conformity

...................................electromagnetic compatibility 

(as per NF EN 61326-1)

Power supply

..............................4 alcaline batteries 1,5V LR6

Operating environment

..............Neutral gas

Operating temperature

...............from 0 to 50°C

Storage temperature

..................from -20 to +80°C

Auto shut-off

...............................adjustable from 0 to 120 min

Weight

..........................................380g

Languages

...................................French, English, and others coming soon. 

Please contact us

Specifications

V, mA

From 0 to 2,5 V
From 0 to 10 V
From 0 to 4/20 mA 

CURRENT / VOLTAGE

PRESSURE

From -200 to +1300°C
From -100 to +750°C
From -200 to +400°C

0.1 °C
0.1 °C
0.1 °C

°C, °F

K :

J :

T :

Measuring units

Measuring range

Accuracy*

Resolutions

Hygro.

%RH

From 5 to 95%RH

 See datasheet  
interchangeable 
measurement modules

0.1 %RH

From 800 to 11,00 hPa

1 hPa

Temp.

From -20 to +80°C

0.1 °C

°C, °F

THERMOCOUPLE

CLIMATIC CONDITIONS

+

0.001 V
0.01 V
0.01 mA

±2mV

±10mV

±0.01mA

±1,1°C or ±0.4% Reading value**
±0.8°C or ±0.4% Reading value**

±0.5°C or ±0.4% Reading value**

hPa

Pa, mmH

2

O, In WG,

mbar, hPa, mmHg, DaPa

kPa, bar, PSI

From 0 to ±500 Pa
From 0 to ±2,500 Pa

1Pa

From 0 to ±10,000 Pa

1Pa

±0.2% of reading ±2Pa

±0.2% of reading ±10Pa

From 0 to ±500 mbar

0,1mbar

±0.3% of reading ±0.5mbar

From 0 to ±2000 mbar

1mbar

±0.3% of reading ±2mbar

± 100 Pa : ±0.2%  of reading ±0.8Pa,
beyond  ±0.2%  of reading ±1,5Pa,

0.1 Pa  from  -100 to +100 Pa, 
1 Pa beyond

Summary of Contents for AMI 300

Page 1: ...Multifunctional IAQ Monitor AMI 300 P a Supplied with Calibration certificate...

Page 2: ...Airflow 11 Area 11 Duct type 11 Sizes 11 K2 factor 11 Units 11 COmax 11 Air velocity 12 Average 12 Point point average 12 Automatic average 12 Automatic point point average 12 Configuration 12 Thermo...

Page 3: ...ug of thermocouple K J or T type Class 1 as per IEC 584 3 Pressure 2 pressure connectors 6 2 mm made of nickel brass 2 threaded pressure connectors 4 6 mm made of nickel brass for 500 and 200 mbar 1 t...

Page 4: ...0 03 area cm2 1 m3 h m3 h cfm l s m3 s 14 mm VANE PROBE PITOT TUBE DEBIMO BLADES C F ppm ppm RH From 20 to 80 C 0 1 C From 0 to 5 000 ppm From 0 to 1 000 ppm From 5 to 95 RH 1 ppm AIR QUALITY PROBES C...

Page 5: ...r protection Top view Module connections mini Din C1 connector Mini Din C2 connector Graphic display Hour Value Unit Channel Circular menu Memory status used Battery level Keypad On Off key Access key...

Page 6: ...2 channels with current voltage input cables or ammeter clamps 2 Pressure module It allows differential pressure air velocity or airflow measurements with Pitot tube or Debimo on two pressure inputs...

Page 7: ...a connection with right and left keys Connections can be activated or deactivated with or Info Measure Params Select a sub menu with access keys Measurement Communication interrupted Check probes conn...

Page 8: ...Del a RF probe B Select a wireless probe already created B1 Power up the RF probe short press on Multifunction button B2 Go to Probe menu B3 With arrows keys and go to RF probes Display All the RF pr...

Page 9: ...ulb globe temperature For hygrometry probe coupled with black ball thermometer If WBGT index is selected press then OK or and a list appears Select Inside or Outside with arrow and Confirm with OK The...

Page 10: ...F with and in order to enable or disable this function Confirm with OK Units K2 factor IV Menus Sizes Press or OK to enter into sizes sub function You can choose an air vent already registered by sele...

Page 11: ...on beforehand defined You must enter duration click on the Period icon Select minutes or seconds with arrow buttons and Scroll digits with and Confirm with OK The numbers of points is displayed Press...

Page 12: ...allows to enable or disable the screen saving Click on OK or to enter and a list appears Enter the delay before the sreen saving activation with and Confirm wih OK Screen Saving IV Menus This sub fun...

Page 13: ...ng Pitot tube Dynamic pressure PT PS Static pressure PS Total pressure PT 1 Connect the pitot tube to AMI 300 2 The probe must be placed at the center of the duct and parallel to the air flow 3 Press...

Page 14: ...ed dataset is displayed From this screen you can Select other dataset using arrow keys and Dislplay data of other channels using arrow keys and d Click on OK to display selected dataset graph From thi...

Page 15: ...r After Sales Service required for appraisal Maintenance Warranty Battery When battery indicator flashes it is recommended to change the batteries 1 Remove the front part at the back of the instrument...

Reviews: