31
6) Service Position:
When it is set to service position by the authorized service, the service icon on the display panel
indicates its activation through blinking.
- It becomes activated when it is pressed for 5 seconds on the “ECO” and “reset” button on the
control panel of your device.
- When the service mode becomes activated, the device directly heats up at maximum. The device
takes itself to minimum when it is pressed for once on the ECO button. It is sufficient to press on the
COMFORT button to set it again back to maximum.
- It may be stopped by pressing on the “reset” button, or it automatically stops by the end of 10
minutes.
Figure 28
This function is only for authorized service.
IMPORTANT NOTE
Your device is required to have been purchased with natural gas or LPG adjustment. In case of asking
usage by propane, device with LPG is requested. The required gas valve settings are made by the
authorized service.
7) Frost Protection:
Along the winter season, when the temperature of water of the fittings decrease below 5°C, frost
protection function steps in, and your device continues to operate until the exiting temperature
of water of fittings increase to 19°C. For the frost protection function to operate, the following
conditions are required to be provided through the control of the customer.
• Electric feeding of the device should be open, and the device should be in “ON” position.
• Gas valve and radiator valves should be open.
• Water pressure of the system should be suitable.
• Frost protection function assists to protect your device, it doesn’t
protect your fittings.
• If the device will not be operated at locations subject to risk of frost, it
is required to empty its water or to use anti-freeze.
MIN
MAX
MIN
MAX
i
COMFORT
ECO
RESET
o
C
ECO
COMFORT