background image

HM

 

Model (Boiler) :

 

Both Central Heating

 

(CH)

 

and 

Domestic Hot

 

Water

 

(DHW).

HCH Model

 

(Heat Only):

 

Only

 

for Central

 

Heating

 

(CH). 

HST

 

Model

 

(System

 

Boiler)

 

:

 

Both

 

for

 

Central

 

Heating

 

(CH)

 

and

 

Domestic

 

Hot

 

Water

 

(DHW)

 

with

 

external 

storage

 

tank

 

(not

 

included).

U

sage information of 14/20/24/28/30/35kW HM-HCH-HST 

Proteus Premix condensing boilers are available in this 

manual. Detailed information have been provided in the 

guide regarding the

 

technical specification of the boiler, 

selection of the boiler location, fitting its water, gas, flue 

and electric

 

supply connections, gas conversion, 

maintenance information and solving of possible failures. 

Please

 

carefully read the manual in order to benefit from 

all the features of your boiler.

The

 

Benchmark

 

Checklist

 

and

 

Service

 

Record

 

Card

 

are

 

located

 

at

 

the

 

back

 

of

 

the

 

Operating

 

Manual. 

The

 

Benchmark

 

Checklist

 

must

 

be

 

filled

 

by

 

gas

 

safe

 

engineer

 

during

 

installation. Operating Manual and 
Service Manual must be handed 
over the user for future operations.

6HUYLFH5HFRUG&DUGPXVWEHILOOHGE\
JDVVDIHHQJLQHHUDQGKDQGHGRYHU
WKHXVHUDIWHUHDFKVHUYLFHRSHUDWLRQ
DQGDQQXDOPDLQWDQHQFH

2

.1

.

 

Installer’s Responsibility

The

 

installer is responsible

 

for the installation and initial 

start-up

 

of

 

the

 

boiler.

 

Instructions are given below.

9

 

Check Operating

 Instructions

,

 

Installation and 

Maintenance

 

Instructions

 and follow instructions before 

installation.

9

 

Carry out installation in compliance with the prevailing 

legislation and standarts.

9

 

Be sure that

 

the system is flushed and inhibitor added.

 

9

 

Only gas safe

 

engineer must

 

operate the boiler.

9

 

Explain

 

the user about installation

 

and operation of 

boiler.

9

 

Fill the Comissioning Checklist.

9

 

Give all Operating and Service manuals to user.

9

 

The warranty certificate must be registered by gas 

safe engineer within 30 days

 

after installation.

SYMBOL 

DEFINITION 

Domestic Hot Water 

Gas Supply 

Parameter Adjustment 

Reset 

Winter Mode 

Summer Mode 

Solar Panel Mode 

ECO Mode 

Comfort Mode 

Ø 

Diameter 

LPG 

Liquid Petroleum Gas 

DHW 

Domestic Hot Water 

NTC 

Negative Temperature 
Coefficient (sensor) 

RCD 

Residual Current 
Device 

ECV 

Emergency Control 
Valve 

SEDBUK

Seasonal Efficiency of 
Domestic Boilers in the 
United Kingdom 

Table 2. Definition of Symbols and Abbreviation 

Indicates that the situation that can only be 
interfered by gas safe 

engineer. 

Explanation

 

containing information that 

should be considered by the 

user.

CAUTION:

 It means that you may suffer 

from material damage or slight

personal injury.

DANGER:

 It means that you may suffer 

from sever personal injury.

 It means that you may connect 

ground wire.

2.2. Definition of Symbols

5

Summary of Contents for PROTEUS PREMIX 14 HM NG ERP UK

Page 1: ...3527 86 35 0 0 67 3527 86 35 0 21 16 1 2 5 23 5 7 1 167RUCTIONS...

Page 2: ...mbi Boiler in Terms of Safety and Energy Consumption 3 2 Clogging in Installation 3 3 Cleaning of Boiler 3 4 Boiler Features 3 5 Additional Recommendations by ECA to Customer To Have High Heating Perf...

Page 3: ...stalled in accordance with national and local requirements gas safety regulations relevant standarts and this manual by gas safe engineer 9 The boiler must be mounted against a closed wall 9 The boile...

Page 4: ...centralheating co uk or installersfirst co uk for more information PRODUCT NAME PRODUCT CODE GC NUMBER PROTEUS PREMIX 14 HM NG ERP UK 8116941010 47 814 30 PROTEUS PREMIX 20 HM NG ERP UK 8116944010 47...

Page 5: ...tial start up of the boiler Instructions are given below 9 Check Operating Instructions Installation and Maintenance Instructions and follow instructions before installation 9 Carry out installation i...

Page 6: ...unauthorized service or staff 3 4 Boiler Features Control panel is ergonomic and easy to use The Proteus Premix condensing boiler with elegant plastic control panel and advanced LCD screen provides ea...

Page 7: ...5 Seasonal Space Heating Energy Efficiency 91 11 91 4 92 2 92 4 92 92 9 Water Heating Energy Efficiency 83 6 83 6 83 6 83 9 82 8 82 8 Sound Power Level db A 49 49 49 49 49 49 Efficiency at Rated Heat...

Page 8: ...pansion Vessel lt 8 Weight Net kg 28 5 28 5 28 5 30 30 32 Weight Net only for HCH model kg 22 5 22 5 22 5 24 24 26 Dimesions HxWxD mm 678 410 288 Flue Lenghts C13 60 100 Max m 10 10 10 10 10 10 C13 80...

Page 9: ...49 Specific precautions for assembly installation and maintanence All specific precautions for installation assembly and maintanence are described in the installation and service manual Proteus Premi...

Page 10: ...on from fiche of solar device III The value of the mathematical expression 294 11 Prated whereby Prated is related to the preferential space heater IV The value of the mathematical expression 115 11 P...

Page 11: ...in this fiche may not correspond to its actual energy efficiency once installed in a building as this efficiency is influenced by further factors such as heat loss in the distribution system and the...

Page 12: ...dimensioning of the products in relation to building size and characteristics I The value of the water heating energy efficiency of the combination heater expressed in II The value of the mathematica...

Page 13: ...Comfort mode Once the Reset button is pressed when operating in Comfort mode the boiler will switch to Eco mode Then when Reset button is pressed again the unit will switch to Comfort mode C Domestic...

Page 14: ...omestic hot water is heating request the tap symbol flashes 1 time sec In this mode the domestic hot water temperature can be adjusted between 30 65 C 7 3 5 Comfort Mode The standard operating mode of...

Page 15: ...is still present or persists after reset notify gas safe engineer 1 Press reset button 2 If the error is still present or persists after reset notify gas safe engineer 1 Check that water valves of boi...

Page 16: ...hen the temperature of the flue gas exceeds 95 o C F07 1 Notify gas safe engineer F13 Repeated Reset Fault Pressing of Reset button more than 5 times in an hour 1 Notify gas safe engineer F25 Electron...

Page 17: ...ue gas The flue gas temperature sensor is in short or open circuit state F53 1 Notify gas safe engineer Flue Gas Lock Out at High Temperature If it gives an error F07 twice in 1 month this error will...

Page 18: ...ny third party who undertakes any work carried on the product or fits parts unless approval is given by the means mentioned in point 5 such work in advance of it being carried out 7 The boiler has to...

Page 19: ...hen be debited from your account i You are required to provide telephone contact numbers to enable us to contact you in the course of arranging and fulfilling your appointment In the course of arrangi...

Page 20: ...si 3 K s m Mustafa Kemal Bulvar No 13 45030 MAN SA 90 236 213 00 21 SALES TECHNICAL SUPPORT Call Center Tel 44 800 640 9988 Office Tel 44 203 978 1212 FW YDW QJ RXU TXDUDQWHH V TX FN DQG V PSOH EXW UH...

Reviews: