6
- USING THE BOILER
6
.1
.
Switching Off the Boiler
You can switch off the boiler by holding down the ON/ OFF
button for 3 seconds.
LCD light will be OFF after 1 minute.
Anti-freeze function remains active.
7
- CONTROL PANEL
Figure 2
Control Panel View
7
.1
.
Functions of
Buttons
The
control
panel
consists
of
the relevant elements
as
shown
in figure 2
below.
A-Position
Selection
Button
The position can be changed by pressing the position selection
button once to change between the winter mode and the
summer mode. If the button is pressed for 3 seconds, the
boiler will switches into "standby" position. It will enough to
press the button once to get the boiler in operation position.
B-Reset
Button
Main functions:
9
Exit from lockout error (EXX)
9
ECO mode activation
9
Comfort mode activation
When your boiler fails, the error code will start flashing on the
display. There are 2 types of errors, lockout (EXX) and blocking
(FXX) error. When a lockout error condition occurs (EXX), the
error must first be corrected so that the error code can be
removed from the LCD screen. After pressing the "Reset" key
once, the boiler can switch back to normal operation state. As
for a blocking error, the fault cannot be removed from the LCD
display pressing the "Reset" button (FXX). When this error is
corrected, error code is automatically disappears from LCD
screen. The first time the boiler starts, it will start working in
Comfort mode.
$
&
'
(
)
%
Once the Reset button is pressed when operating in
Comfort mode, the boiler
will switch to Eco mode.
Then when Reset button is pressed again, the unit will
switch to Comfort mode.
C-Domestic Hot Water Increase Temperature
Button
The temperature of the domestic water can be
increased up to 65 °C thanks to the domestic
water
temperature increase button.
D-Central Heating Water Increase
Temperature Button
The temperature of the heating water can be increased
up to 80 °C thanks to the heating water temperature
increase button.
E- Domestic Hot Water Decrease
Temperature Button
The temperature of the domesti
c water can be
decreased down to 30 °C thanks to the domestic
water
temperature decrease button.
F-Central Heating Water Decrease
Temperature Button
The temperature of the heating water can be
decreased down to 30 °C thanks to the heating
water
temperature decrease button.
7
.2
.
LCD Screen
LCD screen display icons described here below.
Solar Panel Mode
Comfort Mode
ECO Mode
CH Mode ON
RESET
DHW Mode ON
Temperature
Value
Flame
Symbol
Parameter
Settings
Pressure
Display
Figure 2
. Description of Symbols
7
.2.1
.
Flame Icon:
When operating between 0% and
50% capacity range, the icon is displayed on the LCD
screen as single bar, whereas it is displayed as two
bars when operating between 50% -100% capacity
range.
7
.2.2
.
Pressure Indicator:
The LCD display shows
0-0,5-1-1,5-2-2,5-3 bar water pressure values. The
values other than these ones are not displayed.
Only
when filling after F37 (Low water pressure error) fault,
the pressure value is displayed in the temperature
value section.
13