background image

3

- USEFUL INFORMATION ON PRODUCT

3

.1

Efficient Use of the Combi Boiler in Terms of 

Safety and Energy Consumption

Isolation of your building is extremely important. Energy 
saving is achieved at a considerable degree since the 
heat loss is lowest in houses with double-glazed windows 
and insulated walls.

9

 

The use of thermostatic

 

valves in your radiators 

ensures that the room temperature is constant or allows

 

you to save money.

9

 

Turning radiator valves lower levels in the rooms 

which will not be used for a long time and keeping the

 

doors closed keeps fuel consumption low.

9

 

If you use the program clock with your boiler, the 

combi boiler operates at the times you set and

 

consumes less fuel.

9

 

If you use your boiler with room thermostat, it keeps 

the boiler temperature at the level you set and thus

 

allows 

less fuel consumption.

9

 

Covering the radiator top and sides with furniture-like 

things negatively affects hot air circulation, thus

 

prevents 

the environment from overheating and increases fuel 
consumption.

9

 

If you will leave your boiler

 

in operation late at night, 

keeping water temperature of the heating circuit at

 

low 

levels will ensure saving.

9

 

If you feel that the room temperature is high, the 

radiator valves should be closed instead of opening

 

windows.

3

.2

Clogging in Installation

9

 

In old installations with iron pipes, usually clogging 

occurs short time after the boiler

 

is commissioned.

 

9

 

If clogging in installation is encountered with, then 

inhibitor (Sentinel or Fernox etc.) should be added to

 

installation water.

9

 

For further information visit 

www.fernox.com

 

or

 

www.sentinel-solutions.net

3

.3

Cleaning of Boiler

Keep the outer casing of the combi boiler clean by 
wiping it with a soft damped cloth. Do not use strong, 
abrasive cleaning agents.

Performing the maintenance once a year during the 
warranty period and periodically before the winter 
season after the warranty expires ensures safe use, 
saves fuel and extends the useful life of the boiler.

Make sure periodic maintenance is strictly performed by

 

gas safe engineer.

Use original spares parts only to ensure maximum life 
span and safety of the boiler.

E.C.A will not be responsible for damages to boiler
or material or living beings nearby caused by
maintenance performed by unauthorized service or staff.

3.4. 

Boiler

 

Features

Control panel is ergonomic and easy to use. The Proteus 
Premix  condensing  boiler  with  elegant  plastic  control 
panel and  advanced  LCD  screen  provides  ease  of use 
and  service.  On  a  LCD  display

 

with  black  instrument 

panel;  you  can  see  the  operating  state  icons,  heating 
circuit  and  operating  water  adjustment  values, the fault  / 
failure codes  and  the  heating  water  pressure. With the 
safety  systems  available  in  your  boiler, safety  of both  you 
and your boiler are fully ensured.

Flame Failure Safety System

Boiler Over-

Heat Safety System (95 °C)

DHW (Domestic Hot Water) Over-

Heat System (71°C)

High Water Pressure Protection System (3 bar)

Low Water Pressure Protection System (0.4 bar)

Low Voltage Protection System (170 VAC)

Thermal Accumulation Protection System (with by-

pass

circuit and ‘’pump over-run’’)

Frost Protection System for both CH and DHW circuit

Domestic Hot Water Flow Control (only for HM Model)

Pump Anti-sticking Function

3 Way Valve Anti-sticking Function (except HCH

 - HST

Model)

Automatic Air Vent

Expansion Vessel (8 liters)

Water ingress protection from flue

Annual Maintanence Reminder

3.5. A

dditional

 R

ecommendations

 by ECA to 

C

ustomer

 T

o

 H

ave

 H

igh 

H

eating

 P

erformance

:

Make sure that the heating system is clean. Power flushing 

is the most efficient and effective method of cleaning a 

central heating system. The principle is to create a powerful 

fresh water flow under controlled conditions to remove 

debris from the system. By connecting the power flushing 

unit to the heating circuit in place of the system pump, 

boiler or radiator the system can be thoroughly cleaned of 

lime scale and corrosion debris. Without using correct 

water treatment, corrosion debris will accumulate in the 

boiler causing.

Lime scale deposition cause up to 30% of the system's fuel 

consumption being wasted. The noise of boiler increases 

as deposits of sludge and scale build-up in an unprotected 

boiler. The deposits gathering in the waterways of the 

boiler are causing the heat transfer loss and flow noise.

 

In 

your heating system use proposed inhibitors as Fernox and 

Sentinel.

We also advice to use magnetic cleaners for your heating 

system.

Performing the maintenance once a year during the 

warranty period and periodically before the winter season 

after the warranty expires ensures safe use, saves fuel and 

extends the useful life of the boiler. Make sure periodic 

maintenance is strictly performed by E.C.A. Authorized 

Services.

6

Summary of Contents for PROTEUS PREMIX 14 HM NG ERP UK

Page 1: ...3527 86 35 0 0 67 3527 86 35 0 21 16 1 2 5 23 5 7 1 167RUCTIONS...

Page 2: ...mbi Boiler in Terms of Safety and Energy Consumption 3 2 Clogging in Installation 3 3 Cleaning of Boiler 3 4 Boiler Features 3 5 Additional Recommendations by ECA to Customer To Have High Heating Perf...

Page 3: ...stalled in accordance with national and local requirements gas safety regulations relevant standarts and this manual by gas safe engineer 9 The boiler must be mounted against a closed wall 9 The boile...

Page 4: ...centralheating co uk or installersfirst co uk for more information PRODUCT NAME PRODUCT CODE GC NUMBER PROTEUS PREMIX 14 HM NG ERP UK 8116941010 47 814 30 PROTEUS PREMIX 20 HM NG ERP UK 8116944010 47...

Page 5: ...tial start up of the boiler Instructions are given below 9 Check Operating Instructions Installation and Maintenance Instructions and follow instructions before installation 9 Carry out installation i...

Page 6: ...unauthorized service or staff 3 4 Boiler Features Control panel is ergonomic and easy to use The Proteus Premix condensing boiler with elegant plastic control panel and advanced LCD screen provides ea...

Page 7: ...5 Seasonal Space Heating Energy Efficiency 91 11 91 4 92 2 92 4 92 92 9 Water Heating Energy Efficiency 83 6 83 6 83 6 83 9 82 8 82 8 Sound Power Level db A 49 49 49 49 49 49 Efficiency at Rated Heat...

Page 8: ...pansion Vessel lt 8 Weight Net kg 28 5 28 5 28 5 30 30 32 Weight Net only for HCH model kg 22 5 22 5 22 5 24 24 26 Dimesions HxWxD mm 678 410 288 Flue Lenghts C13 60 100 Max m 10 10 10 10 10 10 C13 80...

Page 9: ...49 Specific precautions for assembly installation and maintanence All specific precautions for installation assembly and maintanence are described in the installation and service manual Proteus Premi...

Page 10: ...on from fiche of solar device III The value of the mathematical expression 294 11 Prated whereby Prated is related to the preferential space heater IV The value of the mathematical expression 115 11 P...

Page 11: ...in this fiche may not correspond to its actual energy efficiency once installed in a building as this efficiency is influenced by further factors such as heat loss in the distribution system and the...

Page 12: ...dimensioning of the products in relation to building size and characteristics I The value of the water heating energy efficiency of the combination heater expressed in II The value of the mathematica...

Page 13: ...Comfort mode Once the Reset button is pressed when operating in Comfort mode the boiler will switch to Eco mode Then when Reset button is pressed again the unit will switch to Comfort mode C Domestic...

Page 14: ...omestic hot water is heating request the tap symbol flashes 1 time sec In this mode the domestic hot water temperature can be adjusted between 30 65 C 7 3 5 Comfort Mode The standard operating mode of...

Page 15: ...is still present or persists after reset notify gas safe engineer 1 Press reset button 2 If the error is still present or persists after reset notify gas safe engineer 1 Check that water valves of boi...

Page 16: ...hen the temperature of the flue gas exceeds 95 o C F07 1 Notify gas safe engineer F13 Repeated Reset Fault Pressing of Reset button more than 5 times in an hour 1 Notify gas safe engineer F25 Electron...

Page 17: ...ue gas The flue gas temperature sensor is in short or open circuit state F53 1 Notify gas safe engineer Flue Gas Lock Out at High Temperature If it gives an error F07 twice in 1 month this error will...

Page 18: ...ny third party who undertakes any work carried on the product or fits parts unless approval is given by the means mentioned in point 5 such work in advance of it being carried out 7 The boiler has to...

Page 19: ...hen be debited from your account i You are required to provide telephone contact numbers to enable us to contact you in the course of arranging and fulfilling your appointment In the course of arrangi...

Page 20: ...si 3 K s m Mustafa Kemal Bulvar No 13 45030 MAN SA 90 236 213 00 21 SALES TECHNICAL SUPPORT Call Center Tel 44 800 640 9988 Office Tel 44 203 978 1212 FW YDW QJ RXU TXDUDQWHH V TX FN DQG V PSOH EXW UH...

Reviews: