-WARRANTY AND SERVICE

Warranty Registration 

Scan the QR code to register your 
warranty or visit

 

www.ecaboilers.co.uk

For  Full  Terms  and  Warranty  Conditions 
visit 

www.ecaboilers.co.uk

.

 

The  full  terms 

and  conditions  must  be  strictly  followed  in 
order to manufacturer’s 

warranty valid. 

TERMS AND CONDITIONS FOR WARRANTY of 
ECA Boiler:

1.

The appliance has

 

warranty period against product

failures in condition that the instructions and

 

precautions in

the documents delivered with the product are obeyed. These
documents are operating-installation manual and service
(includes maintenance operation) manual. The warranty
period will not

 

be extended in case of repairing or

replacing any product or part. Manufacturer might
introduce

 

additional warnings/documents in case needed and

deliver with the product. These documents are also

 

binding for

the products delivered with the additional documents.

2.

The appliance has been used for which it is designed.

Heating system inline with product capacity etc.

3.

The installation must be carried out only by a registered Gas

Safe installer. Benchmark Commissioning

 

checklist must be

completed and left with the householder for future reference.
Boiler must be registered

 

by either installer or homeowner

within 30 days of installation to validate warranty. Should this
condition

 

not be met the period of warranty will extend to only

12 months from date of manufacturing on

 

the boiler

 

data plate

(in case proof of purchase or benchmark commissioning
checklist is not available).

4.

At the end of each 12 month period, the boiler must be

serviced by a Gas Safe registered engineer

 

according to

service manual provided with the boiler. After service
operation, Benchmark service record

 

sheet must be

completed and left with the householder. Should this
condition not be met the boiler

 

warranty will lapse.

5.

If the boiler suffers a mechanical or an electrical breakdown

please contact your gas safe

 

engineer on +44 800 640 9988

Our normal working times, excluding Bank Holidays are: 8am

– 5pm Monday to Friday, 8am – 1pm Saturday,We will arrange

for an engineer or appointed contractor,to inspect and repair,

or where in our sole opinion repairis not economic, arrange to

replace the boiler.

6.We will not accept or reimburse the costs of any third party

who undertakes any work carried on the product or fits parts,

unless approval is given by the means mentioned in point 5

such work in advance of it being carried out.

7.

The boiler has to be installed at an accessible

area where Engineers can perform servicing
without

 

health and safety risk.

8.

Cupboard installations must provide minimum

working clearances as detailed in the installation
manual. Homeowner will provide removal of
cupboards, kitchen units or trims in order to gain
access for

 

service.

9.

The warranty does not apply:

a.

If the boiler is removed from its place of

installation and/or installation interfaces have

been changed

 

without our prior consent.

b.

E.C.A will not accept responsibility for damage

caused by faulty installation, neglect, misuse

or

 

accidentaldamage, the non-observance of the

instructions contained in the service manual.

c.

To any defect, damage or breakdown caused by

the installation and maintenance of the CH

system.

d.

Noisy boiler, cold spots on radiators, sludge in

pipes and poor circulation of the central heating

system

 

caused by any damage due to scaling,

sludge or blockages as a result of hard water,

scale, deposits,

 

damage,aggressive water or

sludge due to corrosion. Subsequently

maintenance and cleaning of the

 

system.

e.

If the contact procedure defined in point 5 is not

adhered to

f.

To any other costs or expenses caused by or

arising due to the breakdown of an E.C.A. Boiler.

g.

Damage caused by faulty installation (boiler, flue

system or condensate discharge), theft,

tampering,

 

neglect, misuse, accident, fire, flood,

explosion, lightning, storms, earthquake, frost or

other bad weather

 

conditions.

h.

To any costs incurred during delays in fixing

reported faults.

i.

Costs of each annual maintenance, including

parts such as seals or electrodes replaced at this

time

j.

Any problems caused by inadequate supply of

services such

 

as electricity, gas or

water to the property.

k. The boilers which are not installed and set up

strictly in line with the installation instructions

supplied with them (including the requirement to

clean the system and add corrosion inhibitor in

line with BS7593:1992).

l. Where spare parts other than E.C.A. parts have

been used in any service or repair. In this case,

the warranty for such products is not valid

furthermore.

m. Theft or attempted theft

n. Self-maintenance tasks such as re-pressurizing

and resetting the boiler, bleeding excess system

pressure and thawing frozen condensate pipes.

18

Summary of Contents for PROTEUS PREMIX 14 HM NG ERP UK

Page 1: ...3527 86 35 0 0 67 3527 86 35 0 21 16 1 2 5 23 5 7 1 167RUCTIONS...

Page 2: ...mbi Boiler in Terms of Safety and Energy Consumption 3 2 Clogging in Installation 3 3 Cleaning of Boiler 3 4 Boiler Features 3 5 Additional Recommendations by ECA to Customer To Have High Heating Perf...

Page 3: ...stalled in accordance with national and local requirements gas safety regulations relevant standarts and this manual by gas safe engineer 9 The boiler must be mounted against a closed wall 9 The boile...

Page 4: ...centralheating co uk or installersfirst co uk for more information PRODUCT NAME PRODUCT CODE GC NUMBER PROTEUS PREMIX 14 HM NG ERP UK 8116941010 47 814 30 PROTEUS PREMIX 20 HM NG ERP UK 8116944010 47...

Page 5: ...tial start up of the boiler Instructions are given below 9 Check Operating Instructions Installation and Maintenance Instructions and follow instructions before installation 9 Carry out installation i...

Page 6: ...unauthorized service or staff 3 4 Boiler Features Control panel is ergonomic and easy to use The Proteus Premix condensing boiler with elegant plastic control panel and advanced LCD screen provides ea...

Page 7: ...5 Seasonal Space Heating Energy Efficiency 91 11 91 4 92 2 92 4 92 92 9 Water Heating Energy Efficiency 83 6 83 6 83 6 83 9 82 8 82 8 Sound Power Level db A 49 49 49 49 49 49 Efficiency at Rated Heat...

Page 8: ...pansion Vessel lt 8 Weight Net kg 28 5 28 5 28 5 30 30 32 Weight Net only for HCH model kg 22 5 22 5 22 5 24 24 26 Dimesions HxWxD mm 678 410 288 Flue Lenghts C13 60 100 Max m 10 10 10 10 10 10 C13 80...

Page 9: ...49 Specific precautions for assembly installation and maintanence All specific precautions for installation assembly and maintanence are described in the installation and service manual Proteus Premi...

Page 10: ...on from fiche of solar device III The value of the mathematical expression 294 11 Prated whereby Prated is related to the preferential space heater IV The value of the mathematical expression 115 11 P...

Page 11: ...in this fiche may not correspond to its actual energy efficiency once installed in a building as this efficiency is influenced by further factors such as heat loss in the distribution system and the...

Page 12: ...dimensioning of the products in relation to building size and characteristics I The value of the water heating energy efficiency of the combination heater expressed in II The value of the mathematica...

Page 13: ...Comfort mode Once the Reset button is pressed when operating in Comfort mode the boiler will switch to Eco mode Then when Reset button is pressed again the unit will switch to Comfort mode C Domestic...

Page 14: ...omestic hot water is heating request the tap symbol flashes 1 time sec In this mode the domestic hot water temperature can be adjusted between 30 65 C 7 3 5 Comfort Mode The standard operating mode of...

Page 15: ...is still present or persists after reset notify gas safe engineer 1 Press reset button 2 If the error is still present or persists after reset notify gas safe engineer 1 Check that water valves of boi...

Page 16: ...hen the temperature of the flue gas exceeds 95 o C F07 1 Notify gas safe engineer F13 Repeated Reset Fault Pressing of Reset button more than 5 times in an hour 1 Notify gas safe engineer F25 Electron...

Page 17: ...ue gas The flue gas temperature sensor is in short or open circuit state F53 1 Notify gas safe engineer Flue Gas Lock Out at High Temperature If it gives an error F07 twice in 1 month this error will...

Page 18: ...ny third party who undertakes any work carried on the product or fits parts unless approval is given by the means mentioned in point 5 such work in advance of it being carried out 7 The boiler has to...

Page 19: ...hen be debited from your account i You are required to provide telephone contact numbers to enable us to contact you in the course of arranging and fulfilling your appointment In the course of arrangi...