background image

1-SAFETY RULES AND WARNINGS

1.1

Safety Instructions

When a gas leak is found or suspected;

 

Turn off the gas valve of the boiler and the valves of all 

other devices operating with gas.

 

Shut off the stove, oven and similar appliances to put 

their flame out.

 

Do not light matches, lighter etc, and stub out your 

cigarette.

 

Ventilate the environment by opening doors and 

windows.

 

Do not ever touch the buttons and plugs of your 

electrical appliances.

 

Turn off the gas valves in the apartment and building 

entrance.

 

Do not use the phones at places where the gas leak is 

suspected.

 

Call your gas safe engineer as soon as possible.

 

Do not place and use flammable and explosive liquid or 

materials around the boiler.

 

Keep materials such as water, foam away from 

electrical connections during operations such as 

cleaning, gas leak test etc.

  

  

The boiler must be installed in indoor spaces under normal 

conditions. However, it can be operated in a suitable cabinet 

in places such as garage, open balcony. Please consult 

E.C.A for proper cabine sizes.

 

Do not lay the LPG container down

 

Do not block air vents, openings made in the walls of 

the room which provide fresh air to the installation room.

    

Telephone number of the 

National Gas 

Emergency Service 0800 111 999

1

.2

Water Systems & Gas Supply Line

9

Before installation of the boiler, the water systems 

(CH & DHW circuit) and gas supply line must be

 

completed in accordance with the relevant regulations and 
standards by installer.

9

Installation for gas supply pipes must be fitted 

according to BS6891 for GB and I.S.813.2002 for IE.

Install the connection pipes such that they are free from 

mechanical stress.

1

.3

.

 Gas Type Conversion

9

 

The standard gas type of boiler is Natural Gas. In 

case of a demanding gas type conversion, this is

 

made 

with charge.

9

 

Gas type conversion must be performed by the gas 

safe engineer. Gas leak test must be made after

 

the 

conversion operation.

9

 

Gas conversion label that indicates boiler is converted 

from NG to LPG must be placed on the boiler

 

after gas 

type conversion.

1

.4

.

 Installation 

9

 

The boiler must be installed in accordance with national 

and local requirements, gas safety regulations,

 

relevant 

standarts and this manual by gas safe engineer.

9

 

The boiler must be mounted against a closed wall.

9

 

The boiler can not be positioned having direct contact 

to steam, detergent or gases.

9

 

Any change of flue position must not be made without 

consulting gas safe engineer.

9

 

Sunlight can cause color change on the exterior of your 

boiler over time.

CAUTION: 

This boiler is not intended for 

use  by  persons  (including  children)  who 
are  low  physical  or  sensory  and  mental 
capacity  and  inexperienced  persons 
without informing and supervising the use 
of  the  boiler  by  responsible  persons. 
Ensure that children under 8 years do not 
play with the boiler. 

CAUTION:

 

If boiler

 

is used incorrectly or 

for  other  than  its  intended  use,  it  may 
present  a  life  hazard  and  may  cause 
material damage to the product and its 
surroundings.

CAUTION:

 

The

 

boiler

 

must be 

transported and lifted by at least 2 
people due to heavy weight.

3

If boiler is located in an unheated area, it must be 

connected to mains, switched on, and pressure of 

installation should be within operation range so that freeze 

protection would be activated. Even if boiler is OFF position, 

freeze protection stays activated.

1.5. Boiler Start Up 

 Boiler start up must be performed certainly by gas safe 

engineer.

 Gas Type (Natural Gas / LPG), gas supply pressure 

(mbar), maximum DHW operating water pressure (bar) and 

electricity supply voltage on the information plate must be 

suitable with mains supply conditions. This is checked by 

gas safe engineer.

 After boiler start up, you should request information about 

operating the boiler and safety precautions from gas safe 

engineer.

1.6. Usage and Maintenance 

 Read carefully instructions and precautions in this manual 

against wrong usage which causes unsafe conditions.

 The boiler should be checked and serviced for general 

maintenance once a year. Maintenance and service 

operations must be carried out only gas safe engineer.

 Only a damp cloth should be used for cleaning the outer 

surface of the boiler and then the surfaces should be dried 

completely. Do not use chemical substances or solutions 

which cause rust and scratches in your boiler.

    

Connecting the drain 

pipework for the expansion 

relief val

ve

Summary of Contents for PROTEUS PREMIX 14 HM NG ERP UK

Page 1: ...3527 86 35 0 0 67 3527 86 35 0 21 16 1 2 5 23 5 7 1 167RUCTIONS...

Page 2: ...mbi Boiler in Terms of Safety and Energy Consumption 3 2 Clogging in Installation 3 3 Cleaning of Boiler 3 4 Boiler Features 3 5 Additional Recommendations by ECA to Customer To Have High Heating Perf...

Page 3: ...stalled in accordance with national and local requirements gas safety regulations relevant standarts and this manual by gas safe engineer 9 The boiler must be mounted against a closed wall 9 The boile...

Page 4: ...centralheating co uk or installersfirst co uk for more information PRODUCT NAME PRODUCT CODE GC NUMBER PROTEUS PREMIX 14 HM NG ERP UK 8116941010 47 814 30 PROTEUS PREMIX 20 HM NG ERP UK 8116944010 47...

Page 5: ...tial start up of the boiler Instructions are given below 9 Check Operating Instructions Installation and Maintenance Instructions and follow instructions before installation 9 Carry out installation i...

Page 6: ...unauthorized service or staff 3 4 Boiler Features Control panel is ergonomic and easy to use The Proteus Premix condensing boiler with elegant plastic control panel and advanced LCD screen provides ea...

Page 7: ...5 Seasonal Space Heating Energy Efficiency 91 11 91 4 92 2 92 4 92 92 9 Water Heating Energy Efficiency 83 6 83 6 83 6 83 9 82 8 82 8 Sound Power Level db A 49 49 49 49 49 49 Efficiency at Rated Heat...

Page 8: ...pansion Vessel lt 8 Weight Net kg 28 5 28 5 28 5 30 30 32 Weight Net only for HCH model kg 22 5 22 5 22 5 24 24 26 Dimesions HxWxD mm 678 410 288 Flue Lenghts C13 60 100 Max m 10 10 10 10 10 10 C13 80...

Page 9: ...49 Specific precautions for assembly installation and maintanence All specific precautions for installation assembly and maintanence are described in the installation and service manual Proteus Premi...

Page 10: ...on from fiche of solar device III The value of the mathematical expression 294 11 Prated whereby Prated is related to the preferential space heater IV The value of the mathematical expression 115 11 P...

Page 11: ...in this fiche may not correspond to its actual energy efficiency once installed in a building as this efficiency is influenced by further factors such as heat loss in the distribution system and the...

Page 12: ...dimensioning of the products in relation to building size and characteristics I The value of the water heating energy efficiency of the combination heater expressed in II The value of the mathematica...

Page 13: ...Comfort mode Once the Reset button is pressed when operating in Comfort mode the boiler will switch to Eco mode Then when Reset button is pressed again the unit will switch to Comfort mode C Domestic...

Page 14: ...omestic hot water is heating request the tap symbol flashes 1 time sec In this mode the domestic hot water temperature can be adjusted between 30 65 C 7 3 5 Comfort Mode The standard operating mode of...

Page 15: ...is still present or persists after reset notify gas safe engineer 1 Press reset button 2 If the error is still present or persists after reset notify gas safe engineer 1 Check that water valves of boi...

Page 16: ...hen the temperature of the flue gas exceeds 95 o C F07 1 Notify gas safe engineer F13 Repeated Reset Fault Pressing of Reset button more than 5 times in an hour 1 Notify gas safe engineer F25 Electron...

Page 17: ...ue gas The flue gas temperature sensor is in short or open circuit state F53 1 Notify gas safe engineer Flue Gas Lock Out at High Temperature If it gives an error F07 twice in 1 month this error will...

Page 18: ...ny third party who undertakes any work carried on the product or fits parts unless approval is given by the means mentioned in point 5 such work in advance of it being carried out 7 The boiler has to...

Page 19: ...hen be debited from your account i You are required to provide telephone contact numbers to enable us to contact you in the course of arranging and fulfilling your appointment In the course of arrangi...

Page 20: ...si 3 K s m Mustafa Kemal Bulvar No 13 45030 MAN SA 90 236 213 00 21 SALES TECHNICAL SUPPORT Call Center Tel 44 800 640 9988 Office Tel 44 203 978 1212 FW YDW QJ RXU TXDUDQWHH V TX FN DQG V PSOH EXW UH...

Reviews: