Before installing the drive make sure that the door is in good mechanical condition, as
well as being balanced and make sure it properly opens and closes.
Make sure that the trigger part for the emergency release cannot get caught on the roof
carrier systems or other structures of vehicles thus triggering the emergency release
uncontrollably.
After the installation, make sure that the drive is properly adjusted and the door moves in
the opposite direction, if the door touches an object which has a height of 40 mm above
the floor.
After the installation, make sure that parts of the door do not protrude in public footpaths
or roads.
The relevant regulations for the installation and operation of electrical equipment are to
be followed.
Caution!
The door drive can be operated by children older than eight years of age as well as persons
with restricted physical, sensory or mental capabilities or lack of experience and knowledge if
they have been supervised or instructed in the safe operation of the door and thus
understand and recognise possible risks.
1.3Important safety regulations and rules
Firmly installed control elements (including a wall mounted hand-held transmitter) are to
be installed within sight of the door but away from moving parts and at a height of at least
1.5 m and out of the reach of children.
The triggering device for the emergency release must be affixed at a height of less than
1.8 m. If the triggering device is loose or removable, it must be kept in the immediate
vicinity of the door.
The indicator plate for the emergency release is to be permanently affixed in the
immediate vicinity of the triggering component.
The required socket for the connection of the door drive must be attached approx. 0.5 m
next to the drive.
If the mains cable to the door drive is damaged the drive should not be used. In this case,
the mains cable must be replaced by a qualified and authorised expert.
Warning signs indicating the danger of getting caught are to be permanently placed in an
inconspicuous area or in the immediate vicinity of the control equipment.
4