5
CC 622/622HF M622EN3
Opening pressure, MPa (psi)
Drive system
42,0 (6,100)
Charge system
2,4 (350)
Vibration system
35,0 (5,100)
Steering system
20,0 (2,900)
Brake release
1,5 (220)
TECHNICAL SPECIFICATIONS
Tightening torque
M
STRENGTH CLASS
thread
8.8
10.9
12.9
M6
8,4
12
14,6
M8
21
28
34
M10
40
56
68
M12
70
98
117
M16
169
240
290
M20
330
470
560
M24
570
800
960
M30
1130
1580
1900
M36
1960
2800
–
Tightening torque in Nm (lbf.ft) for oiled, bright
galvanized bolts tightened with a torque wrench.
Hydraulic system
ROPS
Bolt size:
M24 (P/N 903792)
Strength class:
10,9
Tightening torque: 800 Nm (590lbf.ft)
(for Dacromet treated)
ROPS bolts must always be tightened dry.
Air Condition (Optional)
The system described in this manual is of the ACC
type (Automatic Climate Control), ie, a system that
maintains the set temperature in the cab, on condition
that windows and door are kept closed.
Refrigerant designation: HFC-R134:A
Weight of refrigerant newly filled: 1600 gram
Summary of Contents for CC 622