7.2.10 Configuration mode
The configuration mode sets which remote module has the initial control of the system at power up.
The options are:
1.
First in
(default setting) - the remote module that powers the system up has control
2.
Always user
- no matter which remote module powers up the system, the wheelchair occu-
pant will always have initial control
3.
Always attendant
- no matter which remote module powers up the system, the attendant will
always have initial control
4.
DX-like
(last out) - the remote module that has control before powering down resumes control
on power up.
Note
:
The settings in configuration mode are only used when powering up. After a system is powered up, control of a
system can be set with the mode button.
See also
:
7.2.4 Mode button
7.2.7 Attendant indicator
7.2.10.1 Enter configuration mode
Configuration mode can only be entered with the following button press sequence:
[Note that the system must be powered down to begin.]
1. Press and hold the
mode
button.
2. Press and hold the
power
button until both the the mode and power button indicators light
up green.
3. Release the
power
button as soon as the
power
button indicator switches off.
4. Release the
mode
button as soon as the
mode
button indicator switches off.
The battery gauge will light up with the current who's in charge setting.
7.2.10.2 Change who's in charge at start-up
To change who's in charge at start up, press the mode button one or more times to scroll through the
options. The battery gauge colour changes for the four options:
Amber - DX-like
Red - always occupant
Blue - first in
Green - always attendant
7.2.10.3 Exit configuration mode
To exit configuration mode, press the power button once. Alternatively, if there is no activity for 15
seconds, the remote module automatically exits from configuration mode.
The setting is saved automatically on exit.
GBK65701 DX2 Compact Remote Modules
Installation Manual Issue 1
Operation - Page 35