7
SECTION 2
–
SPECIFICATIONS
2.1
Features
•
Eddy current drive digital controller
•
Available in panel and NEMA enclosed configurations
•
Adjustable output voltage from 0
–
90VDC
•
Up to 8 amps output
(see
EC 2000
–
HP
models for higher voltage or current outputs)
•
Ethernet IP add-on available
•
Speed (AC tachometer generator or speed pickup) or torque (clutch current) feedback
permissible
•
Adjustable brake current output
•
Controllable via potentiometer, follower signal (0-10V, 4-20mA), or the keypad
•
115VAC standard power input
•
Digital, noise free operation
•
Fuse and MOV protected
•
Back-lit LCD with keypad user interface
•
Programmable analog and relay outputs for different speeds/states and monitoring.
•
Recorded and displayed faults
2.2
Power and Load Ratings
•
Input voltage: 115VAC, 50/60Hz
•
Input Line Current: 8.0A RMS
•
Output: 8.0A DC Output at 90VDC MAX
•
Inversion and field forcing available to 90VDC
•
“Run” Relay (SPST): 115 VAC or 24 VDC at 5A (Resistive); 150VA Pilot Duty
•
Programmable “F” Relay (SPDT): 2A @ 115 VAC
•
Load Regulation: -0.25% load change from 25% to full load
•
Line Regulation: +/- 1% of rated speed for +/-10% change in line voltage
•
Thermal Drift: +/- 0.05% of rated speed per °C
•
Linearity: +/- 2% of maximum rated speed
•
Minimum Regulated Speed: 25 RPM
•
Linear Acceleration/Deceleration Range: 1% - 200% of top speed/sec
2.3
Electrical Protection
•
Fuses: 10A, 250VAC, Type ABC
•
Metal Oxide Varistors
o
240V, 10kA
o
Used on both input and output
Summary of Contents for EC 2000
Page 6: ...6 Figure 2 EC 2000 Keypad Display ...
Page 12: ...12 SECTION 5 INSTALLATION Figure 3 Standard Panel Dimensions Not to scale ...
Page 13: ...13 Figure 4 Keypad Cutout Template to Scale Inches ...
Page 14: ...14 Figure 5 Keypad Dimensions to Scale ...
Page 17: ...17 Figure 8 Start Stop Jog E STOP Wiring Figure 9 Setpoint Reference Manual Auto Mode Wiring ...