DEVICE DESCRIPTIONS
5-96
PROMATRIX System User Handbook 1.2
Single-Channel Configuration
This configuration is used for spare device switching in single-program installations,
i.e. when a single LF-signal is fed to several power amps. In that case, only one DCS
422R module is being used per spare system, since the inputs of all power amps
included are connected in parallel. The output signal of a power amplifier that fails to operate is switched over to
the corresponding spare amp. The pilot tone signal is generated in the DCS 422R module.
Pilot
Detector
Pilot
Detector
Pilot
Detector
Pilot
Detector
Pilot
Detector
Amp
Pilotgen.
19kHz
Amp
Amp
Amp
Spare
Amp
Prog A
Prog A
Prog A
Prog A
Prog A
The following table shows a listing of needed modules for the design of different spare systems in single-channel
configuration.
DCS 421R
SETUP
SPARE
AMP´s
AMP`s
DCS
400
DCS
405R
DCS
421R
DCS
422R
DCS
423R
1
1-4
1
0
1
1
1
1
Max.64
2 2 1 1 16
2
2-8
1
0
1
2
2
2 Max.60
2 2 1 2 15
3
3-12
1
0
1
3
3
3
Max.56
2 2 1 3 14
4
4-16
1
0
1
4
4
4
Max.52
2 2 1 4 13