DEVICE DESCRIPTIONS
PROMATRIX System Benutzerhandbuch 1.1
5-49
5.2.14 Cable Length
Depending on the utilized paging station model and amount, and in relation to minimal supply voltage and cable-
diameter, different maximum cable lengths are possible. The following tabulations show some examples for
cable-diameters of 0.6 mm and 0.8 mm and with supply voltages of 24 V, respectively of 21.6 V in emergency
supply operation. For precise calculation, a calculation-chart running under MS-EXCEL 97 is provided.
A Single Paging Station On A Single DPM-Line:
Cable type
Paging console model
Cable length (m)
21.6 V emergency
supply
Cable length (m)
24 V
JY(St)Y 4x2x0,6
DPC4510/4106
230
395
DPC4520
225
385
DPC4550
220
375
JY(St)Y 4x2x0,8
DPC4510/4106
410
700
DPC4520
400
690
DPC4550
390
670
A Single Paging S Extension On A Single DPM-Line:
Cable type
Paging console model
Cable length (m)
21.6 V emergency
supply
Cable length(m)
24 V
JY(St)Y 4x2x0,6
D DPC4350
150
260
D DPC4350
150
255
D DPC4350
145
250
JY(St)Y 4x2x0,8
D DPC4350
270
460
D DPC4350
265
455
D DPC4350
260
450
Four Paging Stations DPC4550 (+ Extensions) On A Single DPM-Line:
Cable type
Paging console model
Cable length (m)
21.6 V emergency
supply
Cable length (m)
24 V
JY(St)Y 4x2x0,6
4 x DPC 4550
55
95
4 x DPC4550
+ 4 x DPC4350
25
40
JY(St)Y 4x2x0,8
4 x DPC 4550
95
165
4 x DPC4550
+ 4 x DPC4350
40
75
Summary of Contents for PROMATRIX System