LED TEST

 

This menu item allows  a test of all call ki t  station LED output contacts including call 

station   extension if connected to the call station kit.  Activate the return_k button for 

activating the  LED test,  all LEDs output contact are toggling on and off. Activating the 

r e t u r n _ k   i n p u t   again  deactivates  the  LED  output contact   test  and  returns  to 

the  user  menu. 

 

PASSWORD

 

HINT:   The default  password for enabling the menu items 

Setup Menu

 

and 

Buzzer 

is: 2222

 

Activating the return_k input  opens  the 

Password 

dialog  box  where  the  user  can 

enter  a password by activating the  K e y _ 1   t o   1 0  inputs. (as explained at 
“date/time” settings. Activate the return_k input  to  commit the password. 
 

SETUP  MENU

 

Activating the return_k input  opens  the  Setup  sub  menu,  see  following  section.   

If this menu item is not available, then  it has to  be activated  via the 

Password 

dialog 

box. 

 
 
 

 

3.5

 

  

Setup  menu 

 

 

 

FIRMWARE VERSION

 

This menu item shows  version  of the firmware that  is actually installed in the 

call  station kit. 

 

 

CAN BUS: 

The CAN bus address and the CAN BUS speed are set by hardware switches. 

(see chapter 2.4):  
 

CAN TERMINATION: 

The CAN bus termination is set by a hardware switch. (see chapter 2.4):  

 

 

 

Summary of Contents for PROMATRIX 8000 Series

Page 1: ...PMX CSK PROMATRIX 8000 CALL STATION KIT Owner s Manual...

Page 2: ...ion tables Selection tables Default functions indications Factory presets Block diagram Connections OPERATION LC display Operation mode Call station kit mode configuration User menu Setup menu APPENDI...

Page 3: ...s such as radiators heat registers stoves or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or the grounding type plug A polarized plug has...

Page 4: ...e metal piece metal enclosure respectively between the mains poles has to be 3 mm and needs to be minded at all times The minimum distance between parts carrying mains voltage and any switches or brea...

Page 5: ...ditional alarm keys or key locked switches can be connected connection of an external PTT microphone or audio source loudspeaker connection high resolution LC display user menu allows additional param...

Page 6: ...for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercia...

Page 7: ...sing the external power supply 24VDC is provided to the connected LED s Each LED circuits has short circuit protection Power LED Through Screw terminal Connectors Driven by MIX_PWR_LED 5VDC or 24VDC 2...

Page 8: ...setting S22 CAN address S21 CAN Baud rate CN103 Display connection CN17 Menu keys Alarm keys CN5 LED s switch 13 15 CN4 LED s switch 9 12 CN13 Additional power CN11 LED s switch 5 8 CN10 LED s switch...

Page 9: ...8 CN10 LED s switch 1 4 Connection to Primary and secondary LED Belonging to switch 1 4 CN18 Alarm Fault LED Connection to ALARM button Led Alarm Fault LED s CN12 Menu LED s Speaker Connection to Men...

Page 10: ...be set by DIP switch S22 Set the address conform table 1 1 0 off 1 on S22 Address DIP Switch 4 3 2 1 0 0 0 0 0 0 0 0 1 1 0 0 1 0 2 0 0 1 1 3 0 1 0 0 4 0 1 0 1 5 0 1 1 0 6 0 1 1 1 7 1 0 0 0 8 1 0 0 1 9...

Page 11: ...3 2 4 3 PCA Termination The termination of the last Call station in the chain should be set For the PMX CSK is this done by DIP switch S21 S21 4 set to 0 no termination S21 4 set to 1 PMX CSK termina...

Page 12: ...ed buttons or key locked switches POWER LED Green if power supply active FAULT LED Yellow if a fault occurred ALARM LED Red if alarm is active Microphone Supervised Dynamic microphone Speaker Playback...

Page 13: ...lights green Call station is in program assign mode ESC off No signal can be stopped lights green Pressing the ESC button aborts a signal DEL off No collective call selected lights green Collective ca...

Page 14: ...s 0 disconnected Priority 5 priority for messages Name PMX CSK Password Setup menu password protected Default password 2222 Pre gong signal Off Buzzer On acoustic alert signal Compressor Off Options A...

Page 15: ...2 7 Bock Diagram...

Page 16: ...1 The mix_pwr_LED connections on both ends are similar Both can be used to drive the LED s The additional mix_pwr_LED is provided to enable multiple wire connections Note The Mix_pwr_LED can either be...

Page 17: ...itch connections without any additional resistors etc LED s should be connected as shown in picture 1 2 The 3V3_K connections on both ends are similar Both can be used to drive the Switches The additi...

Page 18: ...SAGES An error within the PROMATRIX 8000 system is indicated by the call station kit in following way The FAULT LED output is toggling on off and a warning signal is a cti vat e d via the loudspeaker...

Page 19: ...cel the editing of a parameter or to move upwards in the menu tree Down_K Down key Closing the Down input stops a currently running audio signal chime alarm text Use the IRIS Net software for configur...

Page 20: ...s and the call station kit input are actually free If single lines or the terminal input are busy with lower priority transmissions the enter return LED will be toggle slowly Whilst making an announce...

Page 21: ...selective call you first have to select areas or groups to which the alarm signal shall be transmitted Afterwards activating the covered ALARM key input starts the selective alarm The corresponding A...

Page 22: ...Net software This represents the most convenient way without any limitation while a call station kit itself offers only limited programming ability For configuring the call station kit via the LC dis...

Page 23: ...OGRAM PROGRAM 1 4 PROGRAM ON Program 1 Program assignment Volume 1 Pre Gong Program 4 Volume 4 Buzzer Date Time SETUP CAN address LCD contrast CAN baudrate LCD brightness CAN termination Firmware vers...

Page 24: ...ram by activating the u p _ k or down_k inputs If there are already areas or groups assigned to the currently selected program the corresponding LED_1outputs are activated Activating a single or sever...

Page 25: ...eturn_k input stores the setting and returns to the user menu HINT This menu item is only available after entering t he cor r e ct password DATE TIME The connected call station kits allow setting the...

Page 26: ...k input opens the Password dialog box where the user can enter a password by activating the K e y _ 1 t o 1 0 inputs as explained at date time settings Activate the return_k input to commit the passwo...

Page 27: ...h of them is used for his own purposes to optimize the system performance The CAN bus has to be terminated with a 120 ohms terminating resistor at both ends If the termination is missing or an imprope...

Page 28: ...CAN bus and audio connections The microphone terminal has to be connected to a corresponding RJ 45 wall outlet using the supplied connection cord 3 m The following figure shows the pin assignment of...

Page 29: ...Illustration 4 4 Assignment of PCA bus jack...

Page 30: ...of the corresponding call station kit must be configured within IRIS Net software Ensure that the correct jumper settings are assigned for the type of microphone used The following figure shows the co...

Page 31: ...station Kit and call station extension side by side The CN200 Call station Kit extension connection must be used to connect a DPC 8120 to the call station kit 3 Connect the CN200 output to the EXT po...

Page 32: ...Nominal Voltage 3 3VDC Max current 100 mA LED s Nominal Drive Current 5 mA for each LED Maximum Drive Current 20 mA for each LED Nominal Drive Voltage 5Volts by internal power supply for 5V point ligh...

Page 33: ...120 180mA 24 V 250mA 18 V Maximum Supply Current Internal Power Supply for Lighting With 5 Extensions DPC 8120 260mA 24 V 350mA 18 V 5 3 ACCESOIRES DPC 8120 Call station extension kit EB DPC button wi...

Page 34: ...ustomer orders contact Customer Service at 49 9421 706 0 Fax 49 9421 706 265 Asia Pacific only For customer orders contact Customer Service at 65 6571 2534 Fax 65 6571 2699 For technical assistance co...

Reviews: