Number Element
Description
7
FAULT button
The FAULT button has the following functions:
•
Resetting a ground fault: Press the FAULT button briefly to
confirm a ground fault. If the ground fault has been
rectified at the output, the GROUND LED switches off
•
Simulation of a fault: While the FAULT button is pressed, a
fault is simulated in the DPA. This makes it possible to
manually switch to corrective mode
•
Setting/displaying the CAN baud rate – see the section
entitled Configuring the CAN baud rate, page 29.
•
Resetting to delivery condition: To reset all settings to
their original configuration on delivery, set the CAN
address to 00. Then press the FAULT button for at least
three seconds to reset all amplifier settings
The FAULT button is protected to prevent it from being pressed
accidentally. Use a pointed object (such as a ballpoint pen) to
press the button.
8
POWER LED
The POWER LED lights up green when the power supply is OK.
PROMATRIX 8000 POWER AMPLIFIER
Safety information | en
9
User manual
19-Aug-13 | 03 | F01U217494