Rated output power, 1 kHz, THD < 0.5%, two
channels driven
500 W
Max. RMS voltage swing, 1 kHz, THD = 0.2%,
without load
56 V
80 V
115 V
Voltage gain, ref. 1 kHz
30.2 dB
33.1 dB
36.2 dB
Input sensitivity, rated power at rated load,
1 kHz
+6 dBu (1.55 Vrms)
THD at rated output power, MBW = 80 kHz,
1 kHz
< 0.5%
IMD-SMPTE, 60 Hz, 7 kHz, half rated output
power
< 1.0%
DIM 30, 3.15 kHz, 15 kHz
< 0.4%
Input level, max.
+18 dBu (6.15 Vrms)
Frequency response, ref. 1 kHz, rated load
50 Hz (-3 dB) to 20 kHz (-6 dB)
Input impedance, active balanced
20 kOhms
Damping factor, 1 kHz, rated load
> 5
Slew rate
24 V/µs
Signal to noise ratio, A-weighted
> 104 dB
Output noise, A-weighted
< -66 dBu
CAN port
10 to 500 kbit/s, 2 x RJ-45
Control port
1 x 8-pin connector
3 control inputs/outputs (max. 60 V/1 A)
2 reference outputs (15 V/100 mA and
GND/100 mA)
1 ready/fault output (max. 30 V/1 A)
Output stage topology
Class-D, transformer, floating
Power requirements
115 V/230 V AC (-10%/+6%), 50 to 60 Hz or
24 V DC (-10%/+30%)
Power consumption, AC and DC
See table below
In-rush current
12 A
In-rush current, after five-second power cycle
7 A
Mains fuse
230 V (-10%/+6%): T5A
115 V (-10%/+6%): T10A
Monitor
•
Rated output voltage
4.5 dBu (1.3 V)
•
Rated load impedance
600 ohms
Ground fault
R < 50 kOhms
34
en | Safety information
PROMATRIX 8000 POWER AMPLIFIER
19-Aug-13 | 03 | F01U217494
User manual
Summary of Contents for DPA 8150
Page 1: ...PROMATRIX 8000 POWER AMPLIFIER en User manual...
Page 2: ......
Page 44: ......