Figure 7.1: Removing the output stage cover
5.
Remove the output stage cover. The following diagram shows the 7-pin terminals in the
device used for configuring the output voltage.
AMP1
AMP2
AMP3
AMP4
Figure 7.2: Terminals for configuring the output voltage
Notice!
Each terminal corresponds to an output channel. The diagram shows the DPA 8412 output
stage with the four terminals AMP 1 to AMP 4. The terminals are seen from the front of the
output stage – numbered in ascending order from left to right. Please also refer to the imprint
on the board. In the case of output stages with two channels or just one, fewer terminals are
present in accordance with the number of channels.
6.
Adjust the wiring of the terminal for the output for which you wish to change the output
voltage. The following diagrams show the correct wiring for the possible output voltages
of 100 V, 70 V, or 50 V.