Figure
4.14-3
Disconnecting
the
Edp
Cable
FFC
from
Camera
FPC
Assembly
Installing
the
Panel
Assembly
Install the panel assembly according to the following procedures:
1.
Place the panel assembly upside down so that the bottom is facing up.
2.
Connect the EDP cable to the panel connector and lock it with lock bar, then adhere the mylar
over the connector to secure it in place as shown in Figure 4.14-2
□
,3
□
,4
3.
Connect the EDP cable FFC to the camera FPC board connector as shown in
Figure 4.14-
3 (9->8->7->6->5)
4.
Pull up the blue release paper of Panel Adhesive from LCD cover as shown in Figure 4.14-4
□
,1