3-3-1 Aging tests and Non-aging tests
The following items are grouped as Aging tests. If you like you can run them simultaneously, repeatedly and with “CPU Stress”.
Aging Tests: HDD PHYSICAL, HDD LOGICAL, MEMORY, USB STORAGE, SD STORAGE, ODD, WIRED LAN, CPU, GRAPHYCAL
DISKPLAY, TIMER.
Other than those, we call them “Non-Aging tests”. Each Non-Aging test is executed only once, and most of the tests require the
user’s intervention.
When you start the test items on "Diagnostic" by clicking [START] button and [Multitask] checkbox is checked, Non-Aging tests
you selected are executed first. Each Non-Aging test runs once in order. When all Non-Aging tests are done, Aging tests you
selected will start.
3-3-2 Each item for the operations [Rev01]
[Rev02]
[All Items Check] check box
Checking this box, you can select or deselect all test items.
[All Detail Check] check box
Checking this box, you can select or deselect all test items in detail.
[Multitask] check box
Only for Aging tests.
If you check this box, the selected Aging-tests will run simultaneously.
If you uncheck it, the selected Aging tests are executed one by one.
[
Pass Count
] edit box
Only for Aging tests
Set the number of times for a test, which allows you to specify from 1 to 999.
Each Aging test runs until reaching "Pass Count" you set.
If you also set "Multitask" option, all selected Aging tests will keep running until
when the last one reaches the "Pass Count".
However, if an Aging test gets error 10 times, the test item will be terminated.
[CPU Stress] check box
Only for Aging tests
Checking this box applies some stress to the CPU during the test.
[Set Battery Off At the End] check box
if you check this box, it will run battery off test/setting once at the end of all tests.
Note: Default is checked. And it will be grayed out and unchecked if no battery
or
the running PC cannot be supported (Currently only YangPass20/30 models are
supported) by this item [Set Battery Off At the End]
.
[START] button
Starts the test.
[LOG] button
Shows the detailed test result or to save it.
[STOP] button
Stops the test during the execution.
This button is effective for each Aging test and at the interval between two
Non-Aging tests.
Diagnostics Time
The elapsed time for the test
Summary of Contents for SATELLITE C50-H
Page 1: ...Chapter 1 Hardware Overview...
Page 17: ...1 Chapter 2 Troubleshooting...
Page 96: ...NO CONT ON 49 PAGE NO 48 Copyright C 2020 Dynabook Inc All Rights Reserved...
Page 99: ...NO CONT ON F PAGE NO 51 Copyright C 2020 Dynabook Inc All Rights Reserved 5 2 5YangPass_15_JP...
Page 116: ...Chapter 4 Replacement Procedures 4...
Page 117: ......
Page 127: ......
Page 140: ......
Page 144: ......
Page 152: ......
Page 156: ......