Maintenance Manual (960-948)
2-17
Troubleshooting Procedures
Procedure 3: Connector Check and Replacement Check
2.9.1 Procedure 1 Check on Windows OS
This procedure checks if the touch screen (provide with some models) is
working properly by using the function of Windows.
Check 1
Make sure the mouse cursor is following your finger when you
move your finger on the display. If it does not work properly, go
to Procedure 2.
Check 2
Make sure the “click” function works properly when you tap the
display with the finger. If it does not work properly, go to
Procedure 2.
2.9.2 Procedure 2 Diagnostic Test Program Execution Check
Execute the Display Test, pressed LCD panel test in the Diagnostic
Program. See Chapter 3,
for information on how to
perform the test.
If an error is detected in the test, go to Procedure 3. If no error is detected,
the display itself is normal.
2.9.3 Procedure 3 Connector Check and Replacement Check
The connection among LCD and board may be disconnected or faulty.
Disassemble the computer following the steps described in Chapter 4,
, and perform the following checks:
Check 1
Make sure the LCD/Webcam cable is securely connected to
CN5390 on the system board.
If the connection is loose, reconnect firmly and restart the computer. If
there is still an error, go to Check 2.
Check 2
The LCD/Webcam cable may be damaged. Replace it with a
new one following the instructions in Chapter 4,
and test the display again. If the problem still exists,
perform Check 3.
Check 3
LCD
<System board>
CN5390
LCD/Webcam Cable