Dymax Edge-Carry Conveyor User Guide
Table 9. Troubleshooting Chart for the Edge-Carry Conveyor
Problem
Possible Cause
Testing
Corrective Action
Conveyor Not
Operating
Main Line Circuit
Breaker deployed
Toggle Power Switch off then on
to reset the Circuit Breaker.
Find out why Breaker is deploying.
Improperly fastened
connections
Check all connections.
Properly fasten Power Cord.
Fuses for Motor
Controller blown
Remove Fuses from Fuse Holders
(located in the left side of Control
Box of unit) and check with an
Ohmmeter.
Replace, if defective.
Chain is Too
Loose
Chain is hung up
Inspect the Chain for any signs of
a mechanical bind.
Resolve bind and continue
operation.
Chain tension needs
adjustment
Visually inspect the Chain for
excessive slack.
Loosen the Locknut on the Chain
Tension Adjustment Screw.
Tighten the Chain by turning the
Adjustment Screw. Tighten the
Locknut when adjustment is
complete.