15
Dymax Edge-Carry Conveyor User Guide
Conveyors Using Fusion Flood Lamps
Refer to the Fusion lamp manual for detailed Irradiator and Power Supply information.
1.
Uncrate and assemble the Conveyor as described in instructions 1 and 2 of the Setup and Interconnect
Section.
2.
Unpack the Fusion Lamp Assembly(ies) (Figure 15). Each Lamp Assembly includes an Irradiator (Lamp)
and Lamp Connector Cord. For dual Fusion units, the Master Lamp Assembly includes an RF Detector, RF
Detector Connector Cord, and Master to Slave Power Supply Connector Cords.
CAUTION:
Each Fusion Lamp Assembly has a fine mesh RF Screen covering the Lamp Face. Great care
should be taken during installation and handling of these units to avoid puncturing or damaging the
Screen. RF energy can be released and system shut-down can occur if the Screen is damaged in any way.
3.
Inspect the Microwave Screen (Figure 16) on the bottom of the Irradiator. No rips or tears are acceptable.
Figure 15. Fusion Lamp Assembly
Figure 16. Microwave Screen
4.
Mount the Irradiator(s) into the
conveyor’s
Lamp Support (Figure 17 and Figure 18). Take particular care
not to damage the protective Screen Covering the lamp end of the Irradiator.
Figure 17. One Irradiator Mounted
Figure 18. Two Irradiators Mounted
5.
Install the RF Detector in the Bracket on the back of the conveyor (if not already installed). Attach the RF
Detector’s Connector Cord to the RF Detector (