9
Dymax Edge-Carry Conveyor User Guide
Electrical Specifications
Table 1. Electrical Requirements
Property
Specification
Conveyor Voltage
Requirements
115 or 220 VAC, 50 or 60 HZ
Conveyor Current
Requirements
Lamp/Power Supply Input
Voltage
100-240 VAC (continuous) Dymax lamp systems
208-240 VAC Fusion lamp systems
Input Current
See Table 6 for individual model numbers
Conveyor & Lamp Total Input
Current
Physical Specifications
Table 2. Physical Requirements
Property
Specification
Model*
UVCS Edge Carry
Cure Width
Up to 12 inches (305 mm)
Number of Lamps
One Dymax 1200-EC or 2000-EC lamps; Up to four Dymax 5000-EC lamps
Up to two Fusion F300 series lamps
Motor Drive
Direct
Chain Speed
1.0
–
32.0 FPM (0.304
–
9.73 m/min.)
Chain Speed (Special Order)
0.5 FPM
–
32 FPM (0.15
–
9.73 m/min)
Chain Speed Display
Red digits, 1 decimal place
Lamp Focus Adjustment
4.0" - 7.5" (102 -191 mm)
Maximum Part Height
6 inches ( 152 mm)**
Exhaust System
1 integral centrifugal blower
*Sixteen different configurations of conveyor are available. Table 3 and Table 4 show all of the possible choices.
** Larger part heights are achievable with the installation of optional riser kits.
The Edge-Carry Conveyor has an adjustable chain width. Different lamp installations can irradiate between 6"
and 12" of that width.