![dymax BlueWave FX-1250 User Manual Download Page 14](http://html.mh-extra.com/html/dymax/bluewave-fx-1250/bluewave-fx-1250_user-manual_2546037014.webp)
14
USE R GUI DE
|
BL UE WAVE
®
F X -1 2 5 0
Status Output
There are three status outputs. They are driven by an optical
coupler. These outputs work in any mode and can be used as
status inputs for PLC or any status display/monitor purpose.
•
WARNING -
Output low indicates the unit is working
normally.
•
Emitter 1 & 2 State -
Output low indicates the UV LEDs
are ON.
An example application of these signals is shown in Figure 15.
PLC Power channel is a 24V source available for use to drive
PLC logic but must be current limited using pull-down resistors
to protect the FX-1250 when directly attached to the I/O
channels through the PLC connector. The support current is
50 mA max
Figure 15.
Status Outputs Connection Using On-Board 24V Source
Figure 16.
PLC Status Outputs Using Customer-Supplied 24V Source
Figure 17.
Examples of Customer Configurations for Monitoring Outputs