A-4
SpycerBox Ultra Hardware Guide
A.2 Technical Data
This section provides technical data of the SpycerBox Ultra.
A.2.1 General Technical Data
The general technical data of the SpycerBox Ultra are as follows:
When installing the DVS system in a rack, take care that
warmed up air is conducted to the rear of the rack and properly
vented away.
Weight
approx. 70 kg
Environment (also
during transport)
No exposure to heat
No exposure to strong electric or magnetic
fields
No vibrations/shocks allowed
Operating
temperature
Maximum:
10 - 30 °C (50 - 86 °F)
Optimum:
15 - 25 °C (59 - 77 °F)
Storage temperature 0 - 50 °C (32 - 122 °F)
Humidity
10 - 80 %, non-condensing at all times
Air
Dust-free
Power consumption max. 3000 W (primary)
nominal 1400 W (primary)
AC power
100 - 120 VAC, 220 - 240 VAC