DVP TDC 150 Operating And Maintenance Instructions Manual Download Page 3

 

 

User and maintenance manual

 

EN

 

TSC - TDC

 

 

 

2

 

 

8702040 – 14/01/2019 – R.7 

www.dvp.it 

 

INTRODUCTION 

 

1.1 

GENERAL INFORMATION  

With this manual we aim to provide you with all the important information regarding the safety of those in charge 
of installation, use, maintenance and dismantling of the TSC and TDC series side channel turbines. 
This manual, issued in ITALIAN, is an integral part of the turbine and must be kept in a safe place for the entirety 
of the machine's lifespan.  
Should the turbine be sold, hired out, or loaned, it must be handed over to the new owner together with the EC 
conformity Declaration.  
Carrying out any operations on the turbine before reading and fully understanding all instructions in this manual is 
prohibited. 
The  images  contained  in  this  document  are  examples  only  and  are  not  binding  for  the  Manufacturer.  The 
Manufacturer reserves the right to make changes to components, make product improvements or for any other 
reason without updating this manual, if said components or parts do not alter the side channel turbine operation 
and safety. 

 

1.2 

MANUFACTURER DATA  

 

D.V.P.  Vacuum  Technology  s.p.a. 

Via Rubizzano, 627 

40018 - S. Pietro in Casale (BO) - ITALY

 

 

Ph

 

+3905118897101

 

Fx

 

+3905118897170

 

e-mail:

 

[email protected]

 

web site:

 

http://www.dvp.it

 

 

Please always include the following information in all communications regarding the turbine: 

  turbine model and serial number; 

  year of manufacture; 

  date of purchase; 

  detailed information regarding problems verified.

 

 

1.3 

CONSULTATION METHODS 

For improved understanding of the information provided in this manual, warnings or instructions considered critical 
or hazardous are marked with the following symbols: 

 

 

HAZARD 
Failure to comply with these instructions may cause hazards to persons. 

 

 

WARNING 
Failure to comply with these instructions may cause damage to the turbine. 

 

1.4 

PERSONNEL QUALIFICATIONS 

To ensure that all operations performed on the turbine are carried out safely, operators must have the qualifications 
and requirements to carry out its operations. 
Operators are classified as follows: 

 

FIRST LEVEL OPERATOR: 

Unqualified personnel, having no specific skills, able to perform simple tasks only.

 

 

MECHANICAL MAINTENANCE OPERATOR: 

Technician qualified to work on mechanical parts to carry out any necessary adjustments, maintenance 
operations or repairs. Not qualified to work on electrical systems in presence of voltage.

 

 

ELECTRICAL MAINTENANCE OPERATOR: 

Qualified  technician  in  charge  of  all  electrical  operations.  Is  capable  of  operating  in  the  presence  of 
voltage inside cabinets and connector boxes.

 

 

 

Summary of Contents for TDC 150

Page 1: ...VACUUM TECHNOLOGY OPERATING AND MAINT ENANCE INSTRUCTIONS Translation of the original instructions SIDE CHANNEL BLOWERS TSC TDC...

Page 2: ...4 3 TRANSPORT AND HANDLING 13 4 4 STORAGE 13 4 5 ENVIRONMENTAL CONDITIONS 13 4 6 TURBINE INSTALLATION 14 4 7 USER SYSTEM 14 4 8 CONNECTION 14 4 8 1 INTAKE AND OUTLET CONNECTION 15 4 8 2 ELECTRIC CONN...

Page 3: ...5118897101 Fx 3905118897170 e mail info dvp it web site http www dvp it Please always include the following information in all communications regarding the turbine turbine model and serial number year...

Page 4: ...y safety requirements in particular it is mandatory that personnel are equipped with personal protective equipment in relation to the activities that must be performed 1 6 IDENTIFICATION PLATE The sid...

Page 5: ...ke and outlet silencers it is possible to access the rotating rotor Never insert your hands or any kind of object through the openings This hazard also exists when the machine is not moving when it is...

Page 6: ...n of the side channel turbine in order to avoid those in charge of works being directly hit by parts or bits of parts flying through the fan cover casing due to the cooling fan breaking 2 3 PICTOGRAMS...

Page 7: ...s other than those indicated in the tables shown in point 3 3 of this manual Do not use the turbine in an explosive or aggressive atmosphere or in an atmosphere with a high concentration of dust or oi...

Page 8: ...115 175 1 1 2 G 284 273 285 0 TSC 210 260 298 115 195 123 250 M8 4 47 175 339 14 120 200 2 G 320 322 332 0 TSC 310 290 332 140 180 113 250 M8 5 50 195 382 14 125 240 2 G 370 362 383 0 TSC 310 1 290 3...

Page 9: ...EN ISO 2151 K 3dB dB A 50Hz dB A 60Hz 52 55 58 61 63 64 70 73 52 55 58 61 63 64 64 65 64 65 Weight kg 7 12 18 27 5 7 12 17 5 19 19 Intake Outlet G 1 1 1 4 1 1 2 2 1 1 1 4 1 1 2 1 1 2 1 1 2 Required w...

Page 10: ...78 74 79 76 81 76 81 Weight kg 26 5 37 5 40 41 83 5 83 5 90 122 133 Intake Outlet G 2 2 2 2 2 1 2 2 1 2 2 1 2 4 4 Required workplace temperature C 0 40 Storage transport room temperature C 20 50 MAX...

Page 11: ...13 79 250 M8 5 50 195 TDC 310 1 290 332 140 180 252 252 218 250 M8 5 98 195 TDC 550 365 420 280 315 307 193 139 350 M12 30 96 280 TDC 550 1 365 420 280 315 307 308 254 350 M12 30 121 280 MODEL H2 HT L...

Page 12: ...A 50Hz dB A 60Hz 60 66 66 69 60 66 66 69 66 69 Weight kg 18 31 18 30 32 5 Intake Outlet G 1 1 4 1 1 2 1 1 4 1 1 2 1 1 2 Required workplace temperature C 0 40 Storage transport room temperature C 20 50...

Page 13: ...0 600 Noise level UNI EN ISO 2151 K 3dB dB A 50Hz dB A 60Hz 74 77 74 77 75 79 75 79 76 81 76 81 Weight kg 43 5 45 56 58 120 149 Intake Outlet G 2 2 2 2 2 1 2 2 1 2 Required workplace temperature C 0 4...

Page 14: ...handling operation must be performed by qualified and experienced personnel It is strictly forbidden to lift the turbine in any way other than that foreseen The side channel turbine can be raised and...

Page 15: ...ironmental conditions or causing discomfort to personnel In order to avoid vacuum or overpressure excesses fit an intake or compression outlet safety valve that allows you to comply with the levels sh...

Page 16: ...are not transmitted on the turbine s attachments WARNING Use an intake filter especially if the turbine works with unclean air flows 4 8 2 ELECTRIC CONNECTION WARNING Check that voltage and frequency...

Page 17: ...e the electric connection box as shown on the side Heat protector specifications NC contact type Intervention temperature 130 5 C Electric contact flow 250Vac 1 A Heat protector connection layout 1 Co...

Page 18: ...ors and or protections and or closure valves Check that the adjustment of the motor protection corresponds with the motor s nominal current indicated on the relative plate Check the correct functionin...

Page 19: ...the power supply to the motor If the turbine is to be turned off let it run with the intake open for about 30 minutes first This will eliminate any moisture inside the intake chamber and avoid the oxi...

Page 20: ...ual HAZARD All maintenance work must be carried out with the turbine disconnected from the power supply and measures must be adopted to prevent it being reconnected Only open the terminal board after...

Page 21: ...y cloth for the container while for the cartridge blowing compressed air aimed in the opposite direction to the conveyed flow s filtering direction that is from the inside outwards Do not use fluids o...

Page 22: ...below you will need to grease the rolling bearings again on the side channel impeller Favourable storage conditions see point 3 3 of this manual 4 years Unfavourable storage conditions high humidity...

Page 23: ...r winding Contact Service Department Intervention of the electric motor protection system The electric motor s protection fuses burn The current absorbed by the electric motor is too high The electric...

Page 24: ...User and maintenance manual EN TSC TDC 23 8702040 14 01 2019 R 7 www dvp it...

Page 25: ...User and maintenance manual EN TSC TDC 24 8702040 14 01 2019 R 7 www dvp it...

Page 26: ...t appear to be faulty due to negligence and or carelessness during use failure to observe the equipment operating instructions lack of maintenance incorrect installation and or maintenance maintenance...

Page 27: ...Cod 8702040 14 01 2019 R 7 EN D V P Vacuum Technology s p a Via Rubizzano 627 40018 San Pietro in Casale BO Italy Ph 3905118897101 Fx 3905118897170 www dvp it...

Reviews: