DVP TDC 150 Operating And Maintenance Instructions Manual Download Page 22

 

 

User and maintenance manual

 

EN

 

TSC - TDC

 

 

 

21

 

 

8702040 – 14/01/2019 – R.7 

www.dvp.it 

 

6.2.6 

CLEANING THE INTAKE AND OUTLET SILENCERS 

Proceed as follows when cleaning the silencers: 

  Stop the turbine and disconnect it from the power supply and user system; 

  Unscrew the intake and outlet flange screws; 

  Remove the silencer cartridges and separate them from the support guards; 

  Clean  the  silencers,  the  support  guards  and  relative  cartridges  using  a  blow  of  compressed  air  (should  the 

cartridges have deteriorated, order new ones); 

  Reconnect  to  the  power  supply  and  verify  the  correct  rotation  direction  of  the  turbine  (see  point  3.3  of  this 

manual); 

  Reconnect to the user system. 

 

6.2.7 

GREASING THE BEARINGS 

If the side channel turbine is fitted with a greaser gun, grease the front bearing with MOBILGREASE XHP220 or 
similar greases (MILLERS OILS – SYNPLEX 2175HT GREASE).  
Proceed as follows to grease the bearings: 

  Stop the turbine and disconnect it from the mains; 

  Remove the escape screw right next to the greaser gun; 

  Proceed  with  greasing  until  the  grease  comes  out  of  the  escape  hole  (usually  only  a  few  cc  of  grease  are 

required); 

  Put the escape hole screw back on; 

  Reconnect  to  the  power  supply  and  verify  the  correct  rotation  direction  of  the  turbine  (see  point  3.3  of  this 

manual). 

 

 

WARNING 
Should the period of time in storage or before starting up exceed the time shown below, you will 
need to grease the rolling bearings again on the side channel impeller.  

 

Favourable storage conditions (see point 3.3 of this manual): 4 years. 

 

Unfavourable storage conditions (high humidity levels, air with saline, sandy or dust content): 
2 years. 

In these cases the open rolling bearings must be greased, while closed ones must be completely 
replaced in line with what is set out below. 

 

6.2.8 

BEARING REPLACEMENT 

Only qualified personnel should replace the bearings. 

 

6.3 

SPARE PARTS 

In order to replace the side channel turbine parts we recommend the use of 

Original Spare Parts

When  purchasing  spare  parts  always  quote  the  turbine's 

Type

  and 

Serial  number

  (you  will  find  these  on  the 

identification plate) as well as the spare parts code.

 

 

DESCRIPTION 

TSC 40 

TSC 80 

1

~

 / TSC 150 

3

~

 / TSC 150/150-1 

TSC 210 

Maintenance 

kit 

K1100001 

K1100002 

K1100013 

K1100003 

K1100004 

 

DESCRIPTION  TSC 310/310-1/310-2  TSC 550/550-0/550-1  TSC 1100/1100-1 

TDC 80 

TDC 150/150-1 

Maintenance 

kit 

K1100005 

K1100006 

K1100007 

K1100008 

K1100009 

 

DESCRIPTION 

TDC 210/210-1 

TDC 310 

TDC 310-1 

TDC 550 

TDC 550-1 

Maintenance 

kit 

K1100010 

K1100011 

K1100014 

K1100012 

K1100015 

 

D.V.P.  Vacuum  Technology  s.p.a.  disclaims  all  responsibility  for  any  deterioration  of  side  channel  turbine 
performance or for damages caused due to use of non-original spare parts. 

 
 
 

RETURNING THE PRODUCT  

 

The product may only be returned after prior agreement with the supplier, who will provide the authorisation number 
that must accompany the material delivered and should be duly completed in its entirety. 

 
 

Summary of Contents for TDC 150

Page 1: ...VACUUM TECHNOLOGY OPERATING AND MAINT ENANCE INSTRUCTIONS Translation of the original instructions SIDE CHANNEL BLOWERS TSC TDC...

Page 2: ...4 3 TRANSPORT AND HANDLING 13 4 4 STORAGE 13 4 5 ENVIRONMENTAL CONDITIONS 13 4 6 TURBINE INSTALLATION 14 4 7 USER SYSTEM 14 4 8 CONNECTION 14 4 8 1 INTAKE AND OUTLET CONNECTION 15 4 8 2 ELECTRIC CONN...

Page 3: ...5118897101 Fx 3905118897170 e mail info dvp it web site http www dvp it Please always include the following information in all communications regarding the turbine turbine model and serial number year...

Page 4: ...y safety requirements in particular it is mandatory that personnel are equipped with personal protective equipment in relation to the activities that must be performed 1 6 IDENTIFICATION PLATE The sid...

Page 5: ...ke and outlet silencers it is possible to access the rotating rotor Never insert your hands or any kind of object through the openings This hazard also exists when the machine is not moving when it is...

Page 6: ...n of the side channel turbine in order to avoid those in charge of works being directly hit by parts or bits of parts flying through the fan cover casing due to the cooling fan breaking 2 3 PICTOGRAMS...

Page 7: ...s other than those indicated in the tables shown in point 3 3 of this manual Do not use the turbine in an explosive or aggressive atmosphere or in an atmosphere with a high concentration of dust or oi...

Page 8: ...115 175 1 1 2 G 284 273 285 0 TSC 210 260 298 115 195 123 250 M8 4 47 175 339 14 120 200 2 G 320 322 332 0 TSC 310 290 332 140 180 113 250 M8 5 50 195 382 14 125 240 2 G 370 362 383 0 TSC 310 1 290 3...

Page 9: ...EN ISO 2151 K 3dB dB A 50Hz dB A 60Hz 52 55 58 61 63 64 70 73 52 55 58 61 63 64 64 65 64 65 Weight kg 7 12 18 27 5 7 12 17 5 19 19 Intake Outlet G 1 1 1 4 1 1 2 2 1 1 1 4 1 1 2 1 1 2 1 1 2 Required w...

Page 10: ...78 74 79 76 81 76 81 Weight kg 26 5 37 5 40 41 83 5 83 5 90 122 133 Intake Outlet G 2 2 2 2 2 1 2 2 1 2 2 1 2 4 4 Required workplace temperature C 0 40 Storage transport room temperature C 20 50 MAX...

Page 11: ...13 79 250 M8 5 50 195 TDC 310 1 290 332 140 180 252 252 218 250 M8 5 98 195 TDC 550 365 420 280 315 307 193 139 350 M12 30 96 280 TDC 550 1 365 420 280 315 307 308 254 350 M12 30 121 280 MODEL H2 HT L...

Page 12: ...A 50Hz dB A 60Hz 60 66 66 69 60 66 66 69 66 69 Weight kg 18 31 18 30 32 5 Intake Outlet G 1 1 4 1 1 2 1 1 4 1 1 2 1 1 2 Required workplace temperature C 0 40 Storage transport room temperature C 20 50...

Page 13: ...0 600 Noise level UNI EN ISO 2151 K 3dB dB A 50Hz dB A 60Hz 74 77 74 77 75 79 75 79 76 81 76 81 Weight kg 43 5 45 56 58 120 149 Intake Outlet G 2 2 2 2 2 1 2 2 1 2 Required workplace temperature C 0 4...

Page 14: ...handling operation must be performed by qualified and experienced personnel It is strictly forbidden to lift the turbine in any way other than that foreseen The side channel turbine can be raised and...

Page 15: ...ironmental conditions or causing discomfort to personnel In order to avoid vacuum or overpressure excesses fit an intake or compression outlet safety valve that allows you to comply with the levels sh...

Page 16: ...are not transmitted on the turbine s attachments WARNING Use an intake filter especially if the turbine works with unclean air flows 4 8 2 ELECTRIC CONNECTION WARNING Check that voltage and frequency...

Page 17: ...e the electric connection box as shown on the side Heat protector specifications NC contact type Intervention temperature 130 5 C Electric contact flow 250Vac 1 A Heat protector connection layout 1 Co...

Page 18: ...ors and or protections and or closure valves Check that the adjustment of the motor protection corresponds with the motor s nominal current indicated on the relative plate Check the correct functionin...

Page 19: ...the power supply to the motor If the turbine is to be turned off let it run with the intake open for about 30 minutes first This will eliminate any moisture inside the intake chamber and avoid the oxi...

Page 20: ...ual HAZARD All maintenance work must be carried out with the turbine disconnected from the power supply and measures must be adopted to prevent it being reconnected Only open the terminal board after...

Page 21: ...y cloth for the container while for the cartridge blowing compressed air aimed in the opposite direction to the conveyed flow s filtering direction that is from the inside outwards Do not use fluids o...

Page 22: ...below you will need to grease the rolling bearings again on the side channel impeller Favourable storage conditions see point 3 3 of this manual 4 years Unfavourable storage conditions high humidity...

Page 23: ...r winding Contact Service Department Intervention of the electric motor protection system The electric motor s protection fuses burn The current absorbed by the electric motor is too high The electric...

Page 24: ...User and maintenance manual EN TSC TDC 23 8702040 14 01 2019 R 7 www dvp it...

Page 25: ...User and maintenance manual EN TSC TDC 24 8702040 14 01 2019 R 7 www dvp it...

Page 26: ...t appear to be faulty due to negligence and or carelessness during use failure to observe the equipment operating instructions lack of maintenance incorrect installation and or maintenance maintenance...

Page 27: ...Cod 8702040 14 01 2019 R 7 EN D V P Vacuum Technology s p a Via Rubizzano 627 40018 San Pietro in Casale BO Italy Ph 3905118897101 Fx 3905118897170 www dvp it...

Reviews: