User and maintenance manual
EN
TSC - TDC
11
8702040 – 14/01/2019 – R.7
www.dvp.it
Model
TDC
80
150
80
150
150-1
1~
3~
Motor power
kW (50Hz)
kW (60Hz)
0,75
0,90
1,5
1,8
0,75
0,90
1,5
1,8
2,2
2,7
Power supply ±5%
V (50Hz)
V (60Hz)
115 / 230
230
220-255 / 380-440
255-277 / 440-480
Absorption
A (50Hz)
A (60Hz)
13 / 6,5
14 / 7
10
11
3,3 / 1,9
3,6 / 2,1
6,7 / 3,9
7,0 / 4,0
7,8 / 4,5
9,5 / 5,5
Nominal capacity
m³/h (50Hz)
m³/h (60Hz)
90
108
150
175
90
108
150
175
150
175
Vacuum
mbar (50Hz)
mbar (60Hz)
200
245
220
250
200
245
275
300
280
350
Overpressure
mbar (50Hz)
mbar (60Hz)
240
245
235
250
240
245
320
300
375
435
Noise level (UNI EN ISO 2151 – K 3dB)
dB(A) 50Hz
dB(A) 60Hz
60
66
66
69
60
66
66
69
66
69
Weight
kg
18
31
18
30
32,5
Ø Intake – Outlet
“G
1-1/4
1-1/2
1-1/4
1-1/2
1-1/2
Required workplace temperature
°C
0 ÷ 40
Storage/transport room temperature
°C
-20 ÷ 50
MAX humidity / altitude
80% / 1000 a.s.l. *
Model
IE2
TDC
150-1
3~
Motor power
kW (50Hz)
kW (60Hz)
2,2
2,7
Power supply ±5%
V (50Hz)
V (60Hz)
400 / 460
Absorption
A (50Hz)
A (60Hz)
4,44 / 4,22
Nominal capacity
m³/h (50Hz)
m³/h (60Hz)
150
175
Vacuum
mbar (50Hz)
mbar (60Hz)
280
350
Overpressure
mbar (50Hz)
mbar (60Hz)
375
420
Noise level (UNI EN ISO 2151 – K 3dB)
dB(A) 50Hz
dB(A) 60Hz
66
69
Weight
kg
32,5
Ø Intake – Outlet
“G
1-1/2
Required workplace temperature
°C
0 ÷ 40
Storage/transport room temperature
°C
-20 ÷ 50
MAX humidity / altitude
80% / 1000 a.s.l. *
(*) Please contact the manufacturer if environmental conditions are different from those prescribed.