DVP TDC 150 Operating And Maintenance Instructions Manual Download Page 26

 

 

GENERAL CONDITIONS OF SALE 

 

D.V.P. Vacuum Technology s.p.a. supplies products exclusively for professional clientele, hence, excluding 
consumers. 
 
 

PRODUCT WARRANTY TERMS AND CONDITIONS 

 

D.V.P.  Vacuum  Technology  s.p.a.  guarantees  that  the  product  is  free  from  material  or  manufacturing 
defects for a period of 24 months of normal use from the shipping date. This period is of 6 months of normal 
use for products subject to repair not under warranty. 
Normal use means an operating cycle of 8 hours per day for a maximum of 5000 operating hours in the 24 
months covered by the warranty. 

 

Warranty  means  the  free  replacement  or  repair  at  its  own  assistance  network  of  any  components  of  the 
product that are found to be faulty from the start due to manufacturing defects. 

 

In  the  event  of  repair,  D.V.P.  Vacuum Technology  s.p.a.  guarantees,  exclusively  to  its  own  customer,  the 
identical spare parts for 24 months from the shipping date; once this period has passed, the pieces may no 
longer be available on the market, therefore the repairs, even under warranty, may require the payment of a 
difference between the product purchased and that installed during the repair.  This price will be indicated 
to the customer before the repair is carried out, for acknowledgement and acceptance.  
D.V.P. Vacuum Technology s.p.a. will do everything reasonable within its power to respect the assistance 
times and 

standard

 response (20 working days), which may vary according to the distance and accessibility 

of the place where the product is located and the availability of the components.  
D.V.P. Vacuum Technology s.p.a. will not be held responsible for any direct or indirect losses caused by its 
failure to respect the assistance times and will not have any responsibility or contractual or civil obligation 
for product faults or for failure to repair the faults in a reasonable period of time. 
 
In  the  event  of  irreparable  faults,  the  product  will  be  replaced.  The  replacement  will  cause  the  original 
warranty to be extended to the new product, until its expiry date. 
 
The  warranty  does  not  cover  any  parts  that  appear  to  be  faulty  due  to  negligence  and/or  carelessness 
during  use  (failure  to  observe  the  equipment  operating  instructions,  lack  of  maintenance),  incorrect 
installation and/or maintenance, maintenance carried out by unauthorized staff, damage due to transport, or 
circumstances which, in any case, cannot be attributed to manufacturing faults on the equipment. 
The warranty also excludes all components of the product that have been modified or repaired without prior 
written authorisation from D.V.P. Vacuum Technology s.p.a. 

 

The warranty also excludes any faults deriving from improper use, normal wear, galvanic and electrostatic 
currents, chemical corrosion, tampering, replacement or elimination of the registration plate. 
The  warranty  does  not  cover,  in  any  case,  faults  generated  by  external  causes,  such  as  accidents  and 
fortuitous events. 

 

D.V.P. Vacuum Technology s.p.a. declines all responsibility to anyone for any damage and, consequence, of 
any  kind  and/or  reason,  that  may  derive  from  the  use  of  the  product,  as  well  as  for  any  faults  that  it  may 
present. 
By way of non-limiting example, it declines all responsibility: 

  for any damage that could, directly or indirectly, be caused to people, objects and animals, due to failure 

to  observe  all  the  instructions  indicated  in  the  relevant  use  and  maintenance  manual,  especially  the 
indications on the installation, use and maintenance of the equipment; 

  for  any  damage  and/or  loss  caused  by  faults  of  deficiencies  of  products  repaired  by  D.V.P.  Vacuum 

Technology s.p.a.; 

  for  any  indirect  or  consequential  damage  such  as,  by  way  of  non-limiting  example,  loss  of  business, 

profits, salaries, payments etc.; 

  losses  that  could  have  been  avoided  by  the  customer  by  following  the  advice  and  instructions  from 

D.V.P. Vacuum Technology s.p.a.. 

In any case, the customer waives the right to claim any right and/or demand as well as raising any objection 
or promoting any action, inherent to the use of the product.  

 

The  warranty  is  not  extended  to  consumable  parts,  or  faults  deriving  from:  filtering  cartridges,  blades, 
membranes or sealing rings, as well as third party products that are part of the final product.  

 

The  transport,  removal  and  subsequent  re-installation  costs  of  the  repaired  or  replaced  product  are, 
however, to be entirely borne by the customer. 

 

 

Summary of Contents for TDC 150

Page 1: ...VACUUM TECHNOLOGY OPERATING AND MAINT ENANCE INSTRUCTIONS Translation of the original instructions SIDE CHANNEL BLOWERS TSC TDC...

Page 2: ...4 3 TRANSPORT AND HANDLING 13 4 4 STORAGE 13 4 5 ENVIRONMENTAL CONDITIONS 13 4 6 TURBINE INSTALLATION 14 4 7 USER SYSTEM 14 4 8 CONNECTION 14 4 8 1 INTAKE AND OUTLET CONNECTION 15 4 8 2 ELECTRIC CONN...

Page 3: ...5118897101 Fx 3905118897170 e mail info dvp it web site http www dvp it Please always include the following information in all communications regarding the turbine turbine model and serial number year...

Page 4: ...y safety requirements in particular it is mandatory that personnel are equipped with personal protective equipment in relation to the activities that must be performed 1 6 IDENTIFICATION PLATE The sid...

Page 5: ...ke and outlet silencers it is possible to access the rotating rotor Never insert your hands or any kind of object through the openings This hazard also exists when the machine is not moving when it is...

Page 6: ...n of the side channel turbine in order to avoid those in charge of works being directly hit by parts or bits of parts flying through the fan cover casing due to the cooling fan breaking 2 3 PICTOGRAMS...

Page 7: ...s other than those indicated in the tables shown in point 3 3 of this manual Do not use the turbine in an explosive or aggressive atmosphere or in an atmosphere with a high concentration of dust or oi...

Page 8: ...115 175 1 1 2 G 284 273 285 0 TSC 210 260 298 115 195 123 250 M8 4 47 175 339 14 120 200 2 G 320 322 332 0 TSC 310 290 332 140 180 113 250 M8 5 50 195 382 14 125 240 2 G 370 362 383 0 TSC 310 1 290 3...

Page 9: ...EN ISO 2151 K 3dB dB A 50Hz dB A 60Hz 52 55 58 61 63 64 70 73 52 55 58 61 63 64 64 65 64 65 Weight kg 7 12 18 27 5 7 12 17 5 19 19 Intake Outlet G 1 1 1 4 1 1 2 2 1 1 1 4 1 1 2 1 1 2 1 1 2 Required w...

Page 10: ...78 74 79 76 81 76 81 Weight kg 26 5 37 5 40 41 83 5 83 5 90 122 133 Intake Outlet G 2 2 2 2 2 1 2 2 1 2 2 1 2 4 4 Required workplace temperature C 0 40 Storage transport room temperature C 20 50 MAX...

Page 11: ...13 79 250 M8 5 50 195 TDC 310 1 290 332 140 180 252 252 218 250 M8 5 98 195 TDC 550 365 420 280 315 307 193 139 350 M12 30 96 280 TDC 550 1 365 420 280 315 307 308 254 350 M12 30 121 280 MODEL H2 HT L...

Page 12: ...A 50Hz dB A 60Hz 60 66 66 69 60 66 66 69 66 69 Weight kg 18 31 18 30 32 5 Intake Outlet G 1 1 4 1 1 2 1 1 4 1 1 2 1 1 2 Required workplace temperature C 0 40 Storage transport room temperature C 20 50...

Page 13: ...0 600 Noise level UNI EN ISO 2151 K 3dB dB A 50Hz dB A 60Hz 74 77 74 77 75 79 75 79 76 81 76 81 Weight kg 43 5 45 56 58 120 149 Intake Outlet G 2 2 2 2 2 1 2 2 1 2 Required workplace temperature C 0 4...

Page 14: ...handling operation must be performed by qualified and experienced personnel It is strictly forbidden to lift the turbine in any way other than that foreseen The side channel turbine can be raised and...

Page 15: ...ironmental conditions or causing discomfort to personnel In order to avoid vacuum or overpressure excesses fit an intake or compression outlet safety valve that allows you to comply with the levels sh...

Page 16: ...are not transmitted on the turbine s attachments WARNING Use an intake filter especially if the turbine works with unclean air flows 4 8 2 ELECTRIC CONNECTION WARNING Check that voltage and frequency...

Page 17: ...e the electric connection box as shown on the side Heat protector specifications NC contact type Intervention temperature 130 5 C Electric contact flow 250Vac 1 A Heat protector connection layout 1 Co...

Page 18: ...ors and or protections and or closure valves Check that the adjustment of the motor protection corresponds with the motor s nominal current indicated on the relative plate Check the correct functionin...

Page 19: ...the power supply to the motor If the turbine is to be turned off let it run with the intake open for about 30 minutes first This will eliminate any moisture inside the intake chamber and avoid the oxi...

Page 20: ...ual HAZARD All maintenance work must be carried out with the turbine disconnected from the power supply and measures must be adopted to prevent it being reconnected Only open the terminal board after...

Page 21: ...y cloth for the container while for the cartridge blowing compressed air aimed in the opposite direction to the conveyed flow s filtering direction that is from the inside outwards Do not use fluids o...

Page 22: ...below you will need to grease the rolling bearings again on the side channel impeller Favourable storage conditions see point 3 3 of this manual 4 years Unfavourable storage conditions high humidity...

Page 23: ...r winding Contact Service Department Intervention of the electric motor protection system The electric motor s protection fuses burn The current absorbed by the electric motor is too high The electric...

Page 24: ...User and maintenance manual EN TSC TDC 23 8702040 14 01 2019 R 7 www dvp it...

Page 25: ...User and maintenance manual EN TSC TDC 24 8702040 14 01 2019 R 7 www dvp it...

Page 26: ...t appear to be faulty due to negligence and or carelessness during use failure to observe the equipment operating instructions lack of maintenance incorrect installation and or maintenance maintenance...

Page 27: ...Cod 8702040 14 01 2019 R 7 EN D V P Vacuum Technology s p a Via Rubizzano 627 40018 San Pietro in Casale BO Italy Ph 3905118897101 Fx 3905118897170 www dvp it...

Reviews: