Safety

This appliance is not intended for use 
by persons (including children) with 
reduced physical, sensory or mental 
capabilities, or lack of experience and 
knowledge, unless they have been given 
supervision or instruction concerning 
use of the appliance by a person 
responsible for their safety.
Children and animals should be 
supervised to ensure that they do not 
interfere with the appliance.

Filling The Water Heater

Open all hot water taps. Open isolating 
valve at the cold water inlet slowly and 
allow water heater to fill until water flows 
through the system. Close each hot 
water tap after the air is expelled from 
its line. As noted previously power is not 
to be turned on until the water heater is 
filled with water.

Water Quality

Your Dux water heater has been 
manufactured to suit water conditions of 
most Australian metropolitan supplies. 
Please note that harsh water supplies 
can have a detrimental effect on the 
water heater and its life expectancy. If 
you are unsure about your water quality 
you can obtain information from your 
local water supply authority.
The water heater is designed for use in 
areas where the Total Dissolved Solids 
(TDS) content of the water supply is 
less than 2500 mg/L. In areas where 

the TDS exceeds 600mg/L it is possible 
that the magnesium alloy anode 
(supplied in the heater) may become 
over-reactive. To alleviate this,a hard-
water model is recommended or the 
magnesium anode should be replaced 
with an aluminium alloy anode.
Water can also be very corrosive, the 
measure of this is the saturation index. 
If the water saturation index is greater 
than 0.40, an expansion control valve 
should be fitted. If the index is greater 
than 0.80, the electrical heating element 
in the water heater should be replaced 
with a low power density Incoloy heating 
element. Please consult our Service 
Department for advice if required.

Caution:

 If the water heater is left in an 

operating condition and unused for two 
weeks or more, a quantity of hydrogen 
(which is highly flammable) may accu-
mulate in the top of the water cylinder. 
To dissipate this gas safely it is recom-
mended that a hot tap be turned on for 
several minutes at a sink, basin or bath, 
but not a dishwasher, clothes washer or 
other appliance. During this procedure 
there must be no smoking, open flame 
or any other electrical appliance operat-
ing nearby. If hydrogen is discharged 
through the tap it will probably make an 
unusual sound as with air escaping.

Where the water heater is not 
installed in accordance with the listed 
advice, the water heater will not be 
covered by the Terms of Warranty. 

Operating Instructions

Summary of Contents for ProFlo series

Page 1: ...6 160S124 160S136 250S136 315S136 315S236 315S248 400S136 400S236 An H at the end of the model number indicates that the water heater is fitted with a hard water anode For advice repairs and service c...

Page 2: ...0421 Rev K Installation Details 1 Plumbing Connections 3 Electrical Connection 5 Specifications 6 Operating Instructions 7 Safety Information 8 Service Information 9 Troubleshooting 10 Warranty 12 Co...

Page 3: ...surance protecting their workmanship for 6 years Make sure you use a licensed person to install this water heater and ask for your Compliance Certificate Water Supply Pressure This water heater is des...

Page 4: ...visible Note All models are equipped with a sacrificial anode accessible through the top cover Allow 50 of the height of the water heater for clearance above to replace the anode The product must be i...

Page 5: ...moved The water heater must not be operated unless this valve is fitted and in working order The PTR Valve should be checked for adequate performance or replaced at intervals not exceeding 5 years or...

Page 6: ...y pipework that is not made of copper Temperature Protection Water heaters can produce very hot water To reduce the risk of scald injury it is mandatory under the requirements of Australian Standard A...

Page 7: ...isengage the top edge Ensure that the conduit entry is well sealed to achieve correct weatherproofing Note This water heater is fitted with a thermostat and over temperature energy cut out Under no ci...

Page 8: ...kg 41 51 61 72 93 93 115 115 Element s Sizes kW 1 8 2 4 3 6 1 8 3 6 2 4 3 6 3 6 3 6 2 3 6 or 2 4 8 3 6 2 3 6 Relief Valve Pressure kPa 1400 1400 1400 1000 1000 1000 1000 1000 Temperature C 99 Power Ra...

Page 9: ...f the water supply is less than 2500 mg L In areas where the TDS exceeds 600mg L it is possible that the magnesium alloy anode supplied in the heater may become over reactive To alleviate this a hard...

Page 10: ...to ensure water is relieved to waste through the relief drain pipe Lower lever gently and check that it closes correctly The PTR Valve must not be tampered with or removed The water heater must not b...

Page 11: ...nditions it is recommended that you carry out a more frequent check of your anode s condition refer Operating Instructions Water Quality Flush the water heater by doing the following i Turn off the po...

Page 12: ...hwashers can be under estimated Review these appliances to determine if your daily usage is greater than the storage volume of your water heater For example if you have a 315 litre storage tank and yo...

Page 13: ...off the electricity supply and contact Dux on 1300 365 115 High Electricity Bills Is the Pressure Temperature Relief Valve discharging too much water Is one outlet such as the shower using more hot w...

Page 14: ...or repair of the Unit other than by an accredited and licensed service agent or technician are not covered Attachment of accessories or use of non genuine replacement parts other than those manufactur...

Page 15: ...les Service option followed by Hot Water Provide the serial number and model number of the HWS located on the white compliance sticker top side of the tank or side of a Continuous Flow unit Provide fu...

Page 16: ...re all your current details are registered with us for prompt warranty service if required To view our privacy policy please visit http www dux com au p privacy or use your smartphone to scan this cod...

Reviews: