Dux ProFlo series Owner'S Manual Download Page 5

Owner’s Manual – Proflo Electric Storage Water Heaters

3

H0421    0421    Rev. K

Plumbing Connections

Pressure & Temperature Relief 
Valve

The Pressure & Temperature Relief Valve 
is supplied loose with the water heater. 
The valve rating is:

80, 125 and 160 litre models: 
 

- 1,400 kPa

250, 315 and 400 litre models: 
 

- 1,000 kPa

The PTR valve must be installed directly 
into the top socket marked “RELIEF 
VALVE”. The drain line from this valve 
must run in a continuously downward 
direction in a frost-free ambient position 
with the discharge end left open to 
atmosphere permanently. 
The PTR Valve is not intended to enable 
connection of the water heater to 
supplementary energy sources such as 
solar panels or slow combustion stoves 
(refer AS/NZS 3500.4 for guidance on 
these types of installations).
After the cold water has been 
connected, open the PTR Valve for 
approximately 10 seconds by lifting the 
lever on the valve to ensure water is 
relieved to waste through the relief drain 
pipe. Lower lever gently and check that it 
closes correctly.
The PTR Valve must not be tampered with 
or removed. The water heater must not 
be operated unless this valve is fitted and 
in working order.

The PTR Valve should be checked for 
adequate performance or replaced at 
intervals not exceeding 5 years, or less in 
areas where local regulations apply. 

Important: 

The PTR Valve and its 

drain outlet pipe must not be sealed or 
blocked. It is normal for the PTR valve 
to leak a small amount of water during 
heating cycles.

Warning:

 A separate drain line must be 

run for this relief valve. It is not permitted 
to couple drain lines from relief valves 
into a single common drain line.

Note: 

Brass plugs are supplied with 

the water heater to plug off the unused 
fittings. Ensure that a sealing material is 
applied to the plugs to prevent leaking.

Cold Water Connection

An approved isolating valve, non 
return valve, line strainer (optional but 
recommended), and union must be 
fitted between the supply main and 
either of the RP¾/20 sockets marked 
“INLET” at the bottom of the water 
heater. All fittings must be approved by 
the relevant Authority. See the diagram 
on page 4 for details.

Note for S.A. and W.A.:

 It is a state 

requirement that a pressure relief valve 
be fitted on the cold water supply line 
between the non return valve and the 
water heater. See the diagram on page 
4 for details.

Summary of Contents for ProFlo series

Page 1: ...6 160S124 160S136 250S136 315S136 315S236 315S248 400S136 400S236 An H at the end of the model number indicates that the water heater is fitted with a hard water anode For advice repairs and service c...

Page 2: ...0421 Rev K Installation Details 1 Plumbing Connections 3 Electrical Connection 5 Specifications 6 Operating Instructions 7 Safety Information 8 Service Information 9 Troubleshooting 10 Warranty 12 Co...

Page 3: ...surance protecting their workmanship for 6 years Make sure you use a licensed person to install this water heater and ask for your Compliance Certificate Water Supply Pressure This water heater is des...

Page 4: ...visible Note All models are equipped with a sacrificial anode accessible through the top cover Allow 50 of the height of the water heater for clearance above to replace the anode The product must be i...

Page 5: ...moved The water heater must not be operated unless this valve is fitted and in working order The PTR Valve should be checked for adequate performance or replaced at intervals not exceeding 5 years or...

Page 6: ...y pipework that is not made of copper Temperature Protection Water heaters can produce very hot water To reduce the risk of scald injury it is mandatory under the requirements of Australian Standard A...

Page 7: ...isengage the top edge Ensure that the conduit entry is well sealed to achieve correct weatherproofing Note This water heater is fitted with a thermostat and over temperature energy cut out Under no ci...

Page 8: ...kg 41 51 61 72 93 93 115 115 Element s Sizes kW 1 8 2 4 3 6 1 8 3 6 2 4 3 6 3 6 3 6 2 3 6 or 2 4 8 3 6 2 3 6 Relief Valve Pressure kPa 1400 1400 1400 1000 1000 1000 1000 1000 Temperature C 99 Power Ra...

Page 9: ...f the water supply is less than 2500 mg L In areas where the TDS exceeds 600mg L it is possible that the magnesium alloy anode supplied in the heater may become over reactive To alleviate this a hard...

Page 10: ...to ensure water is relieved to waste through the relief drain pipe Lower lever gently and check that it closes correctly The PTR Valve must not be tampered with or removed The water heater must not b...

Page 11: ...nditions it is recommended that you carry out a more frequent check of your anode s condition refer Operating Instructions Water Quality Flush the water heater by doing the following i Turn off the po...

Page 12: ...hwashers can be under estimated Review these appliances to determine if your daily usage is greater than the storage volume of your water heater For example if you have a 315 litre storage tank and yo...

Page 13: ...off the electricity supply and contact Dux on 1300 365 115 High Electricity Bills Is the Pressure Temperature Relief Valve discharging too much water Is one outlet such as the shower using more hot w...

Page 14: ...or repair of the Unit other than by an accredited and licensed service agent or technician are not covered Attachment of accessories or use of non genuine replacement parts other than those manufactur...

Page 15: ...les Service option followed by Hot Water Provide the serial number and model number of the HWS located on the white compliance sticker top side of the tank or side of a Continuous Flow unit Provide fu...

Page 16: ...re all your current details are registered with us for prompt warranty service if required To view our privacy policy please visit http www dux com au p privacy or use your smartphone to scan this cod...

Reviews: