Dux ProFlo series Owner'S Manual Download Page 11

Owner’s Manual – Proflo Electric Storage Water Heaters

9

H0421    0421    Rev. K

Service Information

Six Monthly Service (By Owner)

Operate the Pressure & Temperature 
Relief Valve for approximately 10 
seconds by operating the easing lever 
on the valve to ensure water is relieved 
to waste through the relief drain pipe. 
Check to ensure the valve closes 
correctly.

Five Year Service (By Authorised 
Personnel Only)

The five yearly service should be carried 
out by a licensed tradesperson. It is 
recommended that this service be 
carried out by your local Dux agent. 
The service should include the following:
•  Replace the Pressure & Temperature 

Relief Valve.

•  Replace the anode. (in areas of 

harsh or adverse water conditions 
it is recommended that you carry 
out a more frequent check of your 
anode’s condition, refer Operating 
Instructions “Water Quality”)

•  Flush the water heater by doing the 

following:

i.  Turn off the power.
ii.  Turn off the cold water supply to 

the water heater at the isolating 
valve.

iii.  Gently operate the easing lever 

on the Pressure & Temperature 
Relief Valve to release the 
pressure in the water heater.

iv.  Disconnect the cold water inlet 

union to the heater and attach a 
drain hose.

v.  Gently operate the Pressure & 

Temperature Relief Valve to let 
air into the heater and allow 
water to escape through the 
hose.

vi.  To flush the heater, carry out 

steps (i) to (iv) above. Disconnect 
the hot water inlet union and 
attach a water supply hose to 
the heater. Turn on the water 
supply.

vii.  Flush the heater until clear 

water appears. Reconnect 
all fittings, fill the heater and 
restore the electricity supply.

Summary of Contents for ProFlo series

Page 1: ...6 160S124 160S136 250S136 315S136 315S236 315S248 400S136 400S236 An H at the end of the model number indicates that the water heater is fitted with a hard water anode For advice repairs and service c...

Page 2: ...0421 Rev K Installation Details 1 Plumbing Connections 3 Electrical Connection 5 Specifications 6 Operating Instructions 7 Safety Information 8 Service Information 9 Troubleshooting 10 Warranty 12 Co...

Page 3: ...surance protecting their workmanship for 6 years Make sure you use a licensed person to install this water heater and ask for your Compliance Certificate Water Supply Pressure This water heater is des...

Page 4: ...visible Note All models are equipped with a sacrificial anode accessible through the top cover Allow 50 of the height of the water heater for clearance above to replace the anode The product must be i...

Page 5: ...moved The water heater must not be operated unless this valve is fitted and in working order The PTR Valve should be checked for adequate performance or replaced at intervals not exceeding 5 years or...

Page 6: ...y pipework that is not made of copper Temperature Protection Water heaters can produce very hot water To reduce the risk of scald injury it is mandatory under the requirements of Australian Standard A...

Page 7: ...isengage the top edge Ensure that the conduit entry is well sealed to achieve correct weatherproofing Note This water heater is fitted with a thermostat and over temperature energy cut out Under no ci...

Page 8: ...kg 41 51 61 72 93 93 115 115 Element s Sizes kW 1 8 2 4 3 6 1 8 3 6 2 4 3 6 3 6 3 6 2 3 6 or 2 4 8 3 6 2 3 6 Relief Valve Pressure kPa 1400 1400 1400 1000 1000 1000 1000 1000 Temperature C 99 Power Ra...

Page 9: ...f the water supply is less than 2500 mg L In areas where the TDS exceeds 600mg L it is possible that the magnesium alloy anode supplied in the heater may become over reactive To alleviate this a hard...

Page 10: ...to ensure water is relieved to waste through the relief drain pipe Lower lever gently and check that it closes correctly The PTR Valve must not be tampered with or removed The water heater must not b...

Page 11: ...nditions it is recommended that you carry out a more frequent check of your anode s condition refer Operating Instructions Water Quality Flush the water heater by doing the following i Turn off the po...

Page 12: ...hwashers can be under estimated Review these appliances to determine if your daily usage is greater than the storage volume of your water heater For example if you have a 315 litre storage tank and yo...

Page 13: ...off the electricity supply and contact Dux on 1300 365 115 High Electricity Bills Is the Pressure Temperature Relief Valve discharging too much water Is one outlet such as the shower using more hot w...

Page 14: ...or repair of the Unit other than by an accredited and licensed service agent or technician are not covered Attachment of accessories or use of non genuine replacement parts other than those manufactur...

Page 15: ...les Service option followed by Hot Water Provide the serial number and model number of the HWS located on the white compliance sticker top side of the tank or side of a Continuous Flow unit Provide fu...

Page 16: ...re all your current details are registered with us for prompt warranty service if required To view our privacy policy please visit http www dux com au p privacy or use your smartphone to scan this cod...