Dux ProFlo series Owner'S Manual Download Page 12

Owner’s Manual – Proflo Electric Storage Water Heaters

10

H0421    0421    Rev. K

Troubleshooting

What Should I Check Before  
Making A Service Call?

If there is not enough hot water, it is 
recommended that the following points 
be considered before making a service 
call. If after checking the following points 
the problem has not been identified, 
please contact Dux on 1300 365 115.

No Hot Water

•  Is the Pressure & Temperature Relief 

Valve discharging too much water? 

•  Do you have the correct size water 

heater for your requirements? Sizing 
details are available from your Dux 
supplier.

•  Is one outlet (such as the shower) 

using more hot water than you think?

•  Carefully review the family's hot 

water usage and if necessary check 
the shower flow rates with a bucket, 
measuring the amount of water 
used over that period of time. If it is 
not possible to adjust water usage 
patterns, an inexpensive flow control 
valve can easily be fitted to the 
shower outlet.

•  Consider that often the hot water 

usage of showers, washing 
machines and dishwashers can 
be under estimated. Review these 
appliances to determine if your 
daily usage is greater than the 
storage volume of your water 
heater. For example, if you have 
a 315 litre storage tank and you 

are using 450 litres of water it is 
possible that there will be certain 
times of the day where there is 
insufficient hot water. It is also 
advisable to inspect tap washers 
etc. for leakage and replace if 
necessary.

•  Is there a leaking hot water pipe or 

dripping hot water tap? A small leak 
can waste a large quantity of hot 
water.

•  Replace faulty tap washers and have 

your plumber rectify any leaking pipe 
work.

Water Discharge From Pressure & 
Temperature Relief Valve (PTR)

It is not unusual for a small quantity of 
water to discharge during the heating of 
water in your storage tank. The amount 
of discharge will depend on hot water 
usage and size of the storage tank.  
As a guide, it will discharge 3% of the 
storage capacity of water in the heating 
period. 

Continuous Trickle (PTR)

This is most likely due to a build up of 
foreign matter. In this case, try gently 
raising the easing lever on the PTR Valve 
for a few seconds, then release gently. 
This may dislodge a small particle of 
foreign matter and rectify the fault. 

Summary of Contents for ProFlo series

Page 1: ...6 160S124 160S136 250S136 315S136 315S236 315S248 400S136 400S236 An H at the end of the model number indicates that the water heater is fitted with a hard water anode For advice repairs and service c...

Page 2: ...0421 Rev K Installation Details 1 Plumbing Connections 3 Electrical Connection 5 Specifications 6 Operating Instructions 7 Safety Information 8 Service Information 9 Troubleshooting 10 Warranty 12 Co...

Page 3: ...surance protecting their workmanship for 6 years Make sure you use a licensed person to install this water heater and ask for your Compliance Certificate Water Supply Pressure This water heater is des...

Page 4: ...visible Note All models are equipped with a sacrificial anode accessible through the top cover Allow 50 of the height of the water heater for clearance above to replace the anode The product must be i...

Page 5: ...moved The water heater must not be operated unless this valve is fitted and in working order The PTR Valve should be checked for adequate performance or replaced at intervals not exceeding 5 years or...

Page 6: ...y pipework that is not made of copper Temperature Protection Water heaters can produce very hot water To reduce the risk of scald injury it is mandatory under the requirements of Australian Standard A...

Page 7: ...isengage the top edge Ensure that the conduit entry is well sealed to achieve correct weatherproofing Note This water heater is fitted with a thermostat and over temperature energy cut out Under no ci...

Page 8: ...kg 41 51 61 72 93 93 115 115 Element s Sizes kW 1 8 2 4 3 6 1 8 3 6 2 4 3 6 3 6 3 6 2 3 6 or 2 4 8 3 6 2 3 6 Relief Valve Pressure kPa 1400 1400 1400 1000 1000 1000 1000 1000 Temperature C 99 Power Ra...

Page 9: ...f the water supply is less than 2500 mg L In areas where the TDS exceeds 600mg L it is possible that the magnesium alloy anode supplied in the heater may become over reactive To alleviate this a hard...

Page 10: ...to ensure water is relieved to waste through the relief drain pipe Lower lever gently and check that it closes correctly The PTR Valve must not be tampered with or removed The water heater must not b...

Page 11: ...nditions it is recommended that you carry out a more frequent check of your anode s condition refer Operating Instructions Water Quality Flush the water heater by doing the following i Turn off the po...

Page 12: ...hwashers can be under estimated Review these appliances to determine if your daily usage is greater than the storage volume of your water heater For example if you have a 315 litre storage tank and yo...

Page 13: ...off the electricity supply and contact Dux on 1300 365 115 High Electricity Bills Is the Pressure Temperature Relief Valve discharging too much water Is one outlet such as the shower using more hot w...

Page 14: ...or repair of the Unit other than by an accredited and licensed service agent or technician are not covered Attachment of accessories or use of non genuine replacement parts other than those manufactur...

Page 15: ...les Service option followed by Hot Water Provide the serial number and model number of the HWS located on the white compliance sticker top side of the tank or side of a Continuous Flow unit Provide fu...

Page 16: ...re all your current details are registered with us for prompt warranty service if required To view our privacy policy please visit http www dux com au p privacy or use your smartphone to scan this cod...

Reviews: