Owner’s Manual – Proflo Electric Storage Water Heaters

4

H0421    0421    Rev. K

Plumbing Connections

Hot Water Connection

The hot water pipe should be connected 
to either of the RP¾/20 sockets marked 
"OUTLET" at the top of the unit. For the 
most economical operation of the water 
heater, it is recommended that all hot 
water lines are insulated. 
Hot water pipes installed outdoors 
should be insulated with UV stabilised 
insulation.
Please check local regulations regarding 
the use of hot water supply pipework 
that is not made of copper.

Temperature Protection

Water heaters can produce very hot 
water. To reduce the risk of scald injury, 
it is mandatory under the requirements 
of Australian Standard AS/NZS 3500.4 
that a suitably approved temperature 
control device be fitted to the hot water 
supply to outlets used primarily for 
personal hygiene. This valve should be 
checked at regular intervals to ensure its 
operation and settings remain correct. 

Note:

 a combined isolating valve/non-return valve/line strainer may be used. 

Expansion valve only required where local regulations demand although it is 
recommended in areas where the water saturation index is above 0.40.

Inlet Connections

Summary of Contents for ProFlo series

Page 1: ...6 160S124 160S136 250S136 315S136 315S236 315S248 400S136 400S236 An H at the end of the model number indicates that the water heater is fitted with a hard water anode For advice repairs and service c...

Page 2: ...0421 Rev K Installation Details 1 Plumbing Connections 3 Electrical Connection 5 Specifications 6 Operating Instructions 7 Safety Information 8 Service Information 9 Troubleshooting 10 Warranty 12 Co...

Page 3: ...surance protecting their workmanship for 6 years Make sure you use a licensed person to install this water heater and ask for your Compliance Certificate Water Supply Pressure This water heater is des...

Page 4: ...visible Note All models are equipped with a sacrificial anode accessible through the top cover Allow 50 of the height of the water heater for clearance above to replace the anode The product must be i...

Page 5: ...moved The water heater must not be operated unless this valve is fitted and in working order The PTR Valve should be checked for adequate performance or replaced at intervals not exceeding 5 years or...

Page 6: ...y pipework that is not made of copper Temperature Protection Water heaters can produce very hot water To reduce the risk of scald injury it is mandatory under the requirements of Australian Standard A...

Page 7: ...isengage the top edge Ensure that the conduit entry is well sealed to achieve correct weatherproofing Note This water heater is fitted with a thermostat and over temperature energy cut out Under no ci...

Page 8: ...kg 41 51 61 72 93 93 115 115 Element s Sizes kW 1 8 2 4 3 6 1 8 3 6 2 4 3 6 3 6 3 6 2 3 6 or 2 4 8 3 6 2 3 6 Relief Valve Pressure kPa 1400 1400 1400 1000 1000 1000 1000 1000 Temperature C 99 Power Ra...

Page 9: ...f the water supply is less than 2500 mg L In areas where the TDS exceeds 600mg L it is possible that the magnesium alloy anode supplied in the heater may become over reactive To alleviate this a hard...

Page 10: ...to ensure water is relieved to waste through the relief drain pipe Lower lever gently and check that it closes correctly The PTR Valve must not be tampered with or removed The water heater must not b...

Page 11: ...nditions it is recommended that you carry out a more frequent check of your anode s condition refer Operating Instructions Water Quality Flush the water heater by doing the following i Turn off the po...

Page 12: ...hwashers can be under estimated Review these appliances to determine if your daily usage is greater than the storage volume of your water heater For example if you have a 315 litre storage tank and yo...

Page 13: ...off the electricity supply and contact Dux on 1300 365 115 High Electricity Bills Is the Pressure Temperature Relief Valve discharging too much water Is one outlet such as the shower using more hot w...

Page 14: ...or repair of the Unit other than by an accredited and licensed service agent or technician are not covered Attachment of accessories or use of non genuine replacement parts other than those manufactur...

Page 15: ...les Service option followed by Hot Water Provide the serial number and model number of the HWS located on the white compliance sticker top side of the tank or side of a Continuous Flow unit Provide fu...

Page 16: ...re all your current details are registered with us for prompt warranty service if required To view our privacy policy please visit http www dux com au p privacy or use your smartphone to scan this cod...

Reviews: