Ventilator
8.6
Cleaning
– Regularly check the ventilation openings on
the front and rear of the unit for soiling. Clean if
required.
– Remove dirt and dust deposits from the inte-
rior of the unit.
– Wipe the surface of the unit with a damp cloth.
Cleaning agents may cause discolouration of
the surface.
9
Taking out of use
9.1
Taking the unit out of use
If the unit is not to be used for a prolonged
period of time, we is recommend that it be
decommissioned.
❯
Switch on the unit and wait until the cut-off
pressure is reached (see "4 Technical data").
❯
Switch off the unit.
❯
Disconnect the unit from the mains power sup-
ply and secure it so that it cannot be switched
on inadvertently.
❯
Release all of the pressure from the pressure
vessel. To do this, pull the trigger of the clean-
ing gun until the unit is depressurised.
❯
Disconnect the cleaning gun with hose from
the quick-release coupling of the unit.
❯
Open the unit.
❯
Detach the condensate separator (see "8.4
Replacing the fine filter (5 µm) in the conden-
sate separator") and empty the remaining con-
densate from the condensate container.
❯
Re-attach the condensate separator and close
the unit.
9.2
Storage of the unit
WARNING
Risk of explosion of the pressure tank
and pressure hoses
❯
The pressure tank and the pressure
hoses must be vented before they are
stored or transported.
❯
Protect the unit against moisture, dirt and
extreme temperatures during transport (refer to
the section on "Ambient conditions").
❯
Only store the unit when it has been completely
emptied.
Usage
0715100100L02 2111V005
23