8.2
Preparations when replacing
a filter
The following steps need to be carried out
before any maintenance work can be per-
formed on the unit:
❯
Allow the unit to cool down.
❯
Switch off the unit.
❯
Disconnect the mains plug and prevent the unit
from being switched back on again.
❯
Evacuate the unit using e.g. a compressed air
pistol (accessory) connected to the quick-
release coupling until the pressure gauge dis-
plays 0 bar.
❯
Open the lock on the unit cover.
❯
Lift up the unit cover.
12
11
11
Unit cover
12
Unit cover lock
8.3
Replace the air intake filter
cartridge
❯
Pull off the noise reducer from the air intake fil-
ter.
4
18
4
Air intake filter
18
Silencer
❯
Pull the air intake filter cartridge out of the air
intake filter.
4a
4a
Air intake filter cartridge
❯
Insert a new air intake filter cartridge and push
it into the air intake filter.
❯
Push the noise reducer onto the air intake filter
and close the cover of the unit.
Usage
0715100100L02 2111V005
21
EN