Product description
3
Overview
The unit draws in atmospheric air and com-
presses it. The oil-free compressed air is then
transported to the pressure vessel. The oil-free
and filtered air is made available to the consum-
ers in the pressure vessel.
If compressed air is removed for a consumer, the
pressure in the vessel drops. When the switch-on
pressure is reached, the unit is automatically
switched on again via the pressure switch. When
the cut-off pressure is reached, the unit is auto-
matically switched off. A safety valve prevents the
maximum permissible vessel pressure from being
exceeded.
1
2
3
4
6
5
7
Fig. 1: Top view (without unit cover)
1
Pressure vessel
2
Safety Valve
3
Pressure switch
4
Air intake filter
5
Pressure reducer with condensate separa-
tor and fine filter 5 µm
6
Soleinoid valve
7
Operating time counter
10
9
12
11
8
Fig. 2: SICOLAB 062 mini front view
8
Quick-release coupling (choked)
9
On/Off switch
10
Pressure gauge
11
Unit cover
12
Unit cover lock
13
14
15
Fig. 3: View of the rear
13
Carry handle
14
Condensate drain
15
Power plug with fuses
Product description
6
0715100100L02 2111V005
EN