Reconnect the AVR wire clip
Reconnect the wire clip.
7.
Disconnect wires from brush
Remove the 2 wires from the AVR on the carbon brush.
4.
Install new AVR
Install the new AVR with the 2 bolts.
5.
6.
Reconnect wires to brush
Insert and connect the 2 wires from the AVR. Be sure to
c and – correctly.
Changing / Inspecting the AVR (Continued)
TROUBLESHOOTING (CONTINUED)
72