2.1 Side and back walls cladding attachment
1
• Position first sheet and secure it to timber frame using two 25mm Tek Screws at the top corners
(about 30mm back from end of sheet). Top of the sheet to be flush with top of top plate and both
ends flush with outside of studs, ensuring bottom of sheet is approximately 850mm down from
side top plate (TT005).
• Fasten two 25mm Tek Screws 2 ribs up from the bottom of sheet ensuring end of sheet is flush
with outside of studs.
2
• Position the second sheet underneath the first sheet, ensuring top sheet overlaps the outside of the
bottom sheet, and bottom of sheet is approximately 1612mm down from side top plate (TT005).
• Attach the sheet to timber frame using two 25mm Tek Screws at the top corners in the overlap.
• Fasten two 25mm Tek Screws 2 ribs up from the bottom of sheet ensuring end of sheet is flush
with outside of studs.
•Regarding Part IDs refer to the Parts list in pages 4 & 5.