![DuraComm HE1U-5012-BC-MU Product User Manual Download Page 2](http://html1.mh-extra.com/html/duracomm/he1u-5012-bc-mu/he1u-5012-bc-mu_product-user-manual_2540910002.webp)
2
of 23
August 3, 2016
SPECIFICATIONS
Output Voltage........................................................................................................................................................................ 13.8 VDC
Output Voltage Tolerance............................................................................................................................................................+/- 1 %
Output Amperage ............................................................................................................................................................ 50 Amps max.
Maximum Power, continuous .................................................................................................................................................750 Watts
Maximum Ripple and Noise..........................................................................................................................................150 mV p-p max
Input Voltage, Switch Selectable .................................................................................................................................. 110-or 220 VAC
Input Frequency Range ........................................................................................................................................................... 47-63 Hz
Maximum AC Current ..............................................................................................................8.2 Amps/115 VAC; 3.9 Amps/230 VAC
Typical Efficiency............................................................................................................................................................................89 %
Max Inrush Current, single cycle ............................................................................................25 Amps / 115 VAC, 40 Amps / 230VAC
Short Circuit Protection.................................................................................................................................. Constant Current Limiting
Overload Protection (operates) ................................................................................................................................. typical 105-125 %
Line Regulation.........................................................................................................................................................................+/- 0.5 %
Load Regulation .......................................................................................................................................................................+/- 0.5 %
Fan Control.................................................................................................................................... Heat sink temp >140 F (60 C) = ON
Over Temperature ........................................................................................................................ >195 F (90 C) auto output shutdown
Rise Time following ON ................................................................................................................................................................50 mS
Hold Time following OFF ..............................................................................................................................................................10 mS
Working Temperature Range ............................................................................................................. -22 F to +158 F (-30 C to +70 C)
Storage Temperature ......................................................................................................................... -40 F to +185 F (-40 C to +85 C)
Withstand Voltage ..................3 KVAC @ 10 ma (I/P-O/P)/1 min, 2 KVAC @ 10 ma (I/P-FG)/1 min, 500 V @ 10 ma (O/P-FG)/1 min
Dimensions....................................................................................................................................................... 1.75” H x 19” W x 14” D
Weight ......................................................................................................................................................................................... 9.1 lbs
RMCU SPECIFICATIONS
Hardware Revision ............................................................................................................................................................................ 2.0
Firmware Revision............................................................................................................................................................................. 2.7
Network Connector............................................................................................................. RJ-45 (10/100 Ethernet) with activity LEDs
Backup Battery ..........................................................................................................................................................................CR2032
Memory Card................................................................................................................................................................... 4GB Micro SD
Voltage Measurement Range...................................................................................................................................0 VDC to 100 VDC
Current Measurement Range ................................................................................................................................0 Amps to 100 Amps
Digital Alarm input ........................................................................................................................................ Normally Closed Contacts
Alarm Output ...................................................................... Open Collector, 60 VDC Max (REV 2 RMU Hardware), 500 mA sink Max
Alarm Response Time ................................................................................................................................................................. 250ms
Alarm Notifications.................................................................................................................................................. Email and/or SNMP
Logging Rate .............................................................................................................................1 minute resolution, 1 minute to 1 hour
Log Download Format ............................................................................................................... .Comma Separated Values (CSV) File
SNMP MIB File ............................................................................................................................... Download from Device Setup Page
5V Supply Maximum Current...............................................................................................................................................300 mAmps
BATTERY BACK UP & CHARGER
Maximum Power, continuous .................................................................................................................................................750 Watts
Auto-revert to battery or power supply ..................................................................Provided by dual Shottky diode in OR configuration
Maximum output current in battery mode ........................................................................................75 amps (limited by Shottky diode)
Maximum charge voltage ....................................................................................................................................................... 13.8 VDC
Maximum recharge rate................................................................................................................................................................ 2 amp
Note:
The battery charger is a fixed resistance type that provides a tapering current output. A float charge current of 1-2 amps will
be maintained after the battery is charged.
Summary of Contents for HE1U-5012-BC-MU
Page 5: ...5 of 23 August 3 2016...
Page 9: ...9 of 23 August 3 2016 NETWORK SETUP...
Page 12: ...12 of 23 August 3 2016 DEVICE SETUP...
Page 14: ...14 of 23 August 3 2016 SENSOR SETUP...
Page 16: ...16 of 23 August 3 2016 ALARM SETUP...
Page 17: ...17 of 23 August 3 2016...