DUPLOMATIC E.M.DDC4-400V/RK RELEASE 1.9 07-09
EM DDC4-400-RK-0709gb.doc
15
OPERATING FUNCTION N °7: SAFETY
The standard behaviour of the turret can be changed in order to allow the turret to work even if there are
problems mainly on proximity switches.
WARNING: all the functions are intended to be used only in case of effective problems.
The improper use can cause a damage of the turret or the machine.
Proceed as follows:
1. Clear all alarms (if present);
2. Set the operating function:
INPUTS
OPERATING FUNCTION N°7:
MODE01 MODE02 MODE03
SAFETY
1 1 1
3. Select the operation:
n°
PBIT01 PBIT02 PBIT04 PBIT08
PARITY
1
Execute the reference cycle (1)
1 0 0 0 1
2
Disable the management of unlocking switch:
(the unlocking phase is based upon time
instead that switch output) (2)
0 1 0 0 1
3
Disable the management of locking switch:
(the locking phase is based upon time instead
that switch output) (2)
1 1 0 0 0
4
Assume the actual position of the disc as
position number 1 and disable the
management of reference switch (3)
0 0 1 0 1
5
Apply a speed reduction of 30%
1 0 1 0 0
6
Disable the management of the thermal
detector of the motor (4)
0 1 1 0 0
7
Toggle ON/OFF the output of the second digit
of the last alarm. (5)
1 1 1 0 1
8
Toggle ON/OFF the serialize mode (6)
0 0 0 1 1
9
Toggle ON/OFF the output of the status of the
switches (7)
1 0 0 1 0
10
Enable the autotest function (8)
0 1 0 1 0
15
Reset to standard functionality
1 1 1 1 0
4. Set the PSTART signal two times (with a pause of about 50ms. between the two pulses) without changing
the code pattern to activate the function required.
IMPORTANT: there is no confirmation about the correct execution of the operation, because this is intended as
a manual operation with effect that can be easily verified by operator.
All functionality set by this mode will be automatically reset at the power-off of the control unit.
(1) This is an alternative way to execute the reference cycle in CNC in which the tool T 0 is not allowed. In this
case only one PSTART is required.
(2) In this case we assume that the turret is surely locked or unlocked in about 400 ms.
(3) Be sure that the disc is really in position 1, otherwise this operation could be dangerous.
This function can be performed only if the reference cycle has not yet been executed.
(4) Please be sure that thermal detector is broken otherwise this could damage the servomotor.
(5) The second digit of the alarm code is output on the ALBIT1..ALBIT4. A reset will turn-off this function.
Summary of Contents for DDC4-10-400/20
Page 24: ...DUPLOMATIC E M DDC4 400V RK RELEASE 1 9 07 09 EM DDC4 400 RK 0709gb doc 24 SERVOMOTOR CABLE ...
Page 25: ...DUPLOMATIC E M DDC4 400V RK RELEASE 1 9 07 09 EM DDC4 400 RK 0709gb doc 25 DRIVER SUPPLY ...
Page 27: ...DUPLOMATIC E M DDC4 400V RK RELEASE 1 9 07 09 EM DDC4 400 RK 0709gb doc 27 ...
Page 28: ...DUPLOMATIC E M DDC4 400V RK RELEASE 1 9 07 09 EM DDC4 400 RK 0709gb doc 28 ...
Page 30: ...DUPLOMATIC E M DDC4 400V RK RELEASE 1 9 07 09 EM DDC4 400 RK 0709gb doc 30 TIME DIAGRAM ...