background image

12 

 

Eco  Demo  mode  can  be  activated  by  presenting  the 

appliance at exhibitions or in salesrooms. In Eco Demo 
mode, the compressor  and  all fan motors are  switched 
OFF.  

  
By pressing and holding the “

UP

”&“

DOWN

” (The controls 

of  lower  zone  for  dual  zone  &  three  zone  models)  and 

LIGHT

” keys at the same time for  at  least 5  seconds, 

the indicator light will flash five times to confirm the input 
and the unit will operate in Eco Demo mode. Eco Demo 
mode can be exited by repeating the above process.  

  

GENERAL INFORMATION  

 

 

Operating Noises  

The unit is cooled by a compressor (refrigeration 
aggregate). The compressor pumps coolant through the 
cooling system, producing operating noise. Even when 
the compressor cuts out, noises caused by changes in 
temperature and pressure are unavoidable. Operating 
noise will be most audible immediately after the 
compressor cuts in. It becomes quieter as the operating 
period continues.  
  
The following noises are normal and occur from time to 

time:  

-

  Gurgling  sound,  caused  by  the  refrigerant  flowing 

through the appliance’s coils,  

-

  Humming noise made by the motor compressor. This 

noise can get louder for brief periods when the motor 
is switching on.  

-

  Cracking/popping sounds, resulting from the materials 

contraction  and  expansion  due  to  temperature 
variations,  

-

  Fan  operating  sound,  to  circulate  the  air  within  the 

wine cabinet.  

  
Unusual  noise  is  normally  the  result  of  improper 

installation. Under no circumstances  must tubing come 
into  contact  with  a  wall,  other  furniture  or  with  other 
tubing.  

 
Where  the  unit  is  installed  in  open-plan  kitchen  or  in 

partition walls, the level of operating noise will be heard 
more  acutely.  However,  this  is  due  to  the  surrounding 
architecture and not to the unit.  

  

An individual’s perception of noise is directly linked to 

the environment in which the unit is located, as well the 
specific type of models. Our appliances are in line with 
international standards for such appliance and in line 
with the latest technical developments. But please 
remember that the noise of the compressor and the 
coolant circulating in the system is unavoidable.  

 

 

DEFROSTING / HYGROMETRY / 

VENTILATION  

  
Your unit is designed with an automatic defrost system. 

During the “Off-cycle” the evaporator behind the rear wall 
of  the  unit  defrosts  automatically.  The  condensate 
collects  in  the  drain  trough  behind  the  rear  wall  of  the 
unit,  and  part  of  it  flows  through  the  drainage  hole  into 
the  drip  tray  by/above  the  compressor.  The  heat  is 
transferred  from  the discharge  pipe or  compressor  and 

evaporates  any  condensation  that  has  collected  in  the 
tray. Part of the remaining water is collected within the 
unit for humidity purposes.  

  
This system enables the creation of the correct humidity 

level  inside  your  unit  required  by  the  natural  cork  to 
maintain a long lasting seal.  

  
The appliance is not totally sealed: fresh air admission is 

permitted through the drainpipe.  Air is circulated through 
the unit by means of a fan / fans and the hollow shelves.  

 

 

NOTE:

  Frost  may  be  accumulated  on  the  evaporator  if 

the  unit  is  repeatedly  opened  in  a  high  heat  or  high 
humidity location. If this frost pattern does not clear within 
24 hours, your unit will require manual defrosting.  

 

 

CARE AND MAINTENANCE  

 

 

WARNING:

  Failure  to  unplug  the  appliance  during 

service  and  cleaning  could  result  in  electrical  shock  or 
other personal injury.  

  

REMOVING SHELVES 

 

 

  
To remove any of the shelves from the rail compartment, 

move the shelf to the position where the notch of wooden 
shelf is  exactly under the plastic  post  and then lift it  up 
and pull out. 

 

 

  
In  order  to  replace  the  shelf,  repeat  steps  described 

above in reverse. And make sure to engage the shelves 
with the small pegs of the extended rails when the model 
is equipped with roller system.  

  

 

 

HUMIDITY CONTROL  

  
The appliance is equipped with a system for maintaining 

the  correct  level  of  humidity.  Under  extremely  dry 
environmental  conditions,  you  may  have  to  add  some 
water  into  the  humidity  box  provided  with  your  wine 
cellar.  

  
Fill the small plastic reservoir (humidity box) ¾ full with 

water, and fit onto the runners found on the top shelf of 
the appliance.  Check the water level regularly and refill 
as necessary.  

  
Please ensure the reservoir is positioned correctly on the 

runners on the top shelf to avoid the possibility of water 
spillage.  

  
  

Summary of Contents for DAUF-16.52

Page 1: ...rn to its initial position after 3 seconds automatically And the unit will beep once again and it is ready for next opening action NOTE The door will close again automatically after approx 3 seconds if it has not been fully opened manually for models with automatic door closing function Do not block the door or hold on it while it is opening If the door is blocked or held during opening the door o...

Page 2: ...centre or similarly qualified persons in order to avoid a hazard The use of attachments not recommended by the manufacturer may be hazardous Place the unit on a dry level surface Do not operate if the housing is removed or damaged A loose fit between the AC outlet receptacle and plug may cause overheating and a distortion of the plug Contact a qualified electrician to replace loose or worn outlet ...

Page 3: ... disconnect the appliance from the power supply before servicing SAVE THESE INSTRUCTIONS If you are experiencing problems check the Troubleshooting Guide at the back of this manual It lists causes of minor operating problems that you can correct by yourself DISPOSAL Dispose of your appliance packaging properly Ensure that any plastic wrappings bags etc are disposed of safely and kept out of the re...

Page 4: ...ource let it stand upright for at least 24 hours This will reduce the possibility of a malfunction in the cooling system caused by handling during transportation During this time we recommend that you leave the door open to clear any residual odors The door on this appliance can be opened from either the left or the right side The unit is delivered with the door opening on the left side Should you...

Page 5: ...ult in the risk of electrical shock If the power cord is damaged have it replaced by a qualified electrician or an authorized service center All electrical work should be carried out by a suitably qualified and competent person in accordance with local and national safety regulations Check that the voltage marked on the product corresponds with your supply voltage Connect this appliance to a separ...

Page 6: ...lock on the ventilation grille Fig 4 7 Rotate the door 180 No need for models with lock on the door and relocate the door to the designated position Then screw the bottom hinge assembly on the left designated position and tighten it after the door is leveled 8 Transfer the handle plugs to the opposite positions if need DESIGN 2 For fully integrated models 1 Remove the glass door by unscrewing the ...

Page 7: ...amage Then remove the right top hinge 10 Fig 5 4 4 Unscrew and transfer the middle hinge 12 and the middle fixing plate 11 to the opposite position Fig 5 5 Pop out the cover caps on the left side of cabinet and use them to cover the screw holes on the right hand side 6 Screw the alternative left top hinge 9 included in the fittings on the left hand side of cabinet Fig 4 7 Relocate the door adapter...

Page 8: ...crease cool the set temperature by 1 C 1ºF Display Display the digital temperature and service indicators Indicator Light The indicator light is located at the right lower corner of the display The indicator light will be on when the multi key function is selected To perform the multikey function press and hold the first key then press the other key for at least 5 seconds and then release all the ...

Page 9: ...ng white and red wine at a setting of 13 C to 20 C 55 F to 68 F The UPPER LEFT temperature zone is suitable for storing champagne and white wine at a setting of 5 C to 13 C 41 F to 55 F When the unit is plugged in for the first time the unit will power up automatically to the preset defaults The preset temperature at the factory for UPPER LEFT temperature zone is 10ºC 50ºF and for LOWER RIGHT temp...

Page 10: ... The display flashes while you make the setting After the temperature has been set the display shows the current inner temperature of the particular temperature zone To view the set temperature at any time press the UP or DOWN key the set temperature will temporarily flash in the display for 5 seconds Then the display shows the current inner temperature again TEMPERATURE DISPLAY During normal oper...

Page 11: ...r wine bottles in single row or by stacking while taking note of the following if you do not have enough bottles to fill your wine cellar it is better to distribute the load throughout the wine cellar so as to avoid all on top or all below type loads Do remove or relocate adjustable wooden racks to accommodate larger type of bottles or increase the capacity of the cellar by stacking the bottles up...

Page 12: ...olant circulating in the system is unavoidable DEFROSTING HYGROMETRY VENTILATION Your unit is designed with an automatic defrost system During the Off cycle the evaporator behind the rear wall of the unit defrosts automatically The condensate collects in the drain trough behind the rear wall of the unit and part of it flows through the drainage hole into the drip tray by above the compressor The h...

Page 13: ...ker switch etc and then powered up again the unit will operate with the last temperature set point Most power failures are corrected within a few hours and should not affect the temperature of your appliance if you minimize the number of times the door is opened If the power is going to be off for a longer period of time you need to take the proper steps to protect your contents NOTE Irrespective ...

Page 14: ...en The door is not closed completely The door gasket does not seal properly Put the appliance in a cooler place Leave the appliance to work for a while until the set temperature has been reached Do not open the door more often than necessary Close door properly Check the door seal and clean or replace The light does not work Appliance is not connected to a power supply The circuit breaker tripped ...

Page 15: ...reached The icon is lit up and flashing in the temperature display The display temperature is out of the range Only temperatures within the range 0 99 F 9 37 C the appliance can display will be shown If the temperature is not within this range the icon will be displayed instead That is normal WARRANTY The warranty does not cover 1 Damage in transit or when moving the appliance 2 Any damages caused...

Reviews: